Interfacial impedance engineering in ionic hydrogels for integrated enzymatic and electrophysiological sensing
Biosensors and Bioelectronics · 2026-09 · 308 · 118797
DOI: 10.1016/j.bios.2026.118797 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-09. Verfasst von N Aina Afiqah Amran und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Faculty of Science, Universiti Malaya, Kuala Lumpur, 50603, Malaysia. Hauptthemen laut MEDLINE: Biosensing Techniques, Hydrogels, Glucose, Lactic Acid. Die Arbeit nennt 36 Literaturangaben. Gefördert von: Universiti Malaya.
Abstract (Originalsprache)
Interfacial charge-transfer resistance remains a critical bottleneck in wearable enzymatic biosensors, particularly in soft, deformable systems, where impedance instability limits signal amplification. Here, we introduce an impedance-engineered dual-network ionic hydrogel designed to deliberately modulate ionic conductivity and charge-transfer resistance (Rct) at the bioelectronic interface. Incorporation of tetrabutylammonium bromide (TBAB) into a chitosan/PEGDE/AAm-co-AA matrix increased ionic conductivity to ∼8.5 × 10-3 S cm-1 and reduced Rct to ∼190 Ω, demonstrating a quantitative structure-impedance-sensitivity relationship. The optimized hydrogel achieved a glucose sensitivity of 31 ± 2 μA mM-1 cm-2 over the 0.1-10 mM range, a detection limit of 18 μM, and a rapid response time (t90 = 3.2 s), representing a >3-fold enhancement over the undoped control. Beyond biochemical sensing, the ionically continuous interface enabled strain-dependent electrical modulation (ΔR/R0 ≈ 0.65 at 60% strain) and high-fidelity ECG acquisition with a signal-to-noise ratio of ∼47 dB. A dual glucose-lactate configuration demonstrated selective and additive responses within the same electrolyte layer. The lactate-sensing channel exhibited a linear response over the range 0.1-6 mM, a detection limit of approximately 12 μM, and rapid response kinetics, confirming efficient multimodal sensing within an integrated soft biointerface. Supporting machine-learning analysis identified Rct and ionic conductivity as dominant determinants of sensitivity, validating impedance modulation as a scalable materials-level design principle for multifunctional wearable biointerfaces.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, Faculty of Science, Universiti Malaya, Kuala Lumpur, 50603, Malaysia.
- Department of Chemistry, Faculty of Science, Universiti Malaya, Kuala Lumpur, 50603, Malaysia; Institute of Nanotechnology & Catalysis Research (NanoCat), University of Malaya, Kuala Lumpur, 50603, Malaysia.
- Department of Chemistry, Faculty of Science, Universiti Malaya, Kuala Lumpur, 50603, Malaysia. Electronic address: ndiana13@um.edu.my.
Förderung
- Universiti Malaya
Zitieren
APA
Amran, N. A. A., Zaini Ambia, N. F. A., Basirun, W. J., Ariffin, A., & Nordin, N. (2026). Interfacial impedance engineering in ionic hydrogels for integrated enzymatic and electrophysiological sensing. Biosensors and Bioelectronics, 308, 118797. https://doi.org/10.1016/j.bios.2026.118797
Vancouver
Amran NAA, Zaini Ambia NFA, Basirun WJ, Ariffin A, Nordin N. Interfacial impedance engineering in ionic hydrogels for integrated enzymatic and electrophysiological sensing. Biosensors and Bioelectronics. 2026;308:118797. doi:10.1016/j.bios.2026.118797
BibTeX
@article{Amran2026,
author = {Amran, N Aina Afiqah and Zaini Ambia, N Fairuz Ain and Basirun, Wan Jeffrey and Ariffin, Azhar and Nordin, Nurdiana},
title = {Interfacial impedance engineering in ionic hydrogels for integrated enzymatic and electrophysiological sensing},
journal = {Biosensors and Bioelectronics},
year = {2026},
volume = {308},
pages = {118797},
doi = {10.1016/j.bios.2026.118797}
}
EUVIMED