EUVIMEDEUVIMED entdecken
Crossref

Fiber-Optic Photoacoustic Gas Microprobe Based on Linear Spot-Type Multipass Cell

Heng Wang, Yufu Xu, Jingya Zhang, Xinyu Zhao, Zhaodong Zhang, Ke Chen iD

Analytical Chemistry · 21.01.2025 · 97 (2) · 1300-1308

DOI: 10.1021/acs.analchem.4c05486 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 09.01.2025. Verfasst von Heng Wang und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, Liaoning 116024, China. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 57 Literaturangaben. Gefördert von: Natural Science Foundation of Liaoning Province, Fundamental Research Funds for the Central Universities, National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A linear spot-type multipass cell-enhanced fiber-optic photoacoustic gas microprobe is proposed. To further reduce the volume of the gas chamber and enhance the photoacoustic signal, we designed the cross section of the photoacoustic tube as a slit with a height of 10 mm and a width of 1.5 mm. The volume of the gas chamber is only 210 μL. Through theoretical analysis and multiphysical field simulation, the photoacoustic intensity of the slit cross section is more than 6 times that of traditional circular cross section. A cantilever beam is integrated into the photoacoustic microprobe and forms a Fabry-Perot (FP) interferometer with an optical fiber, achieving enhanced photoacoustic detection. By adjusting the angle of the collimator, the light passes through the photoacoustic cell 26 times, and 13 linear spots are formed on the reflecting surface. The photoacoustic signal with multiple linear reflections is 12.4 times that of a single reflection. The gas enters the sensor in a freely diffused manner, and the response time of the sensing system is 54 s. When the averaging time is 400 s, the detection limit of the designed sensor for acetylene gas reaches 1.5 ppb. The minimum detectable absorption coefficient (αmin) and the normalized noise equivalent absorption coefficient (NNEA) are 1.7 × 10-8 cm-1 and 1.9 × 10-9 Wcm-1/Hz1/2, respectively.

Autor:innen und Institutionen

  • School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, Liaoning 116024, China.

ORCID-Profile: Ke Chen

Förderung

  • Natural Science Foundation of Liaoning Province
  • Fundamental Research Funds for the Central Universities
  • National Natural Science Foundation of China

Zitieren

APA

Wang, H., Xu, Y., Zhang, J., Zhao, X., Zhang, Z., & Chen, K. (2025). Fiber-Optic Photoacoustic Gas Microprobe Based on Linear Spot-Type Multipass Cell. Analytical Chemistry, 97(2), 1300-1308. https://doi.org/10.1021/acs.analchem.4c05486

Vancouver

Wang H, Xu Y, Zhang J, Zhao X, Zhang Z, Chen K. Fiber-Optic Photoacoustic Gas Microprobe Based on Linear Spot-Type Multipass Cell. Analytical Chemistry. 2025;97(2):1300-1308. doi:10.1021/acs.analchem.4c05486

BibTeX
@article{Wang2025,
  author = {Wang, Heng and Xu, Yufu and Zhang, Jingya and Zhao, Xinyu and Zhang, Zhaodong and Chen, Ke},
  title = {Fiber-Optic Photoacoustic Gas Microprobe Based on Linear Spot-Type Multipass Cell},
  journal = {Analytical Chemistry},
  year = {2025},
  volume = {97},
  number = {2},
  pages = {1300--1308},
  doi = {10.1021/acs.analchem.4c05486}
}