Ultrasensitive Fiber-Optic Photoacoustic Gas Sensor Based on Miniaturized Dual-Enhancement Spectrophone
IEEE Sensors Journal · 15.06.2025 · 25 (12) · 21464-21472
DOI: 10.1109/jsen.2025.3566410 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 15.06.2025. Verfasst von Beilei Yang und 10 weiteren Autor:innen. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 54 Literaturangaben. Gefördert von: National Nature Science Foundation of China, Natural Science Foundation of Zhejiang Province, Science and Technology Planning Project of Shaoxing City.
Abstract (Originalsprache)
A fiber-optic photoacoustic sensor (FOPAS) based on a miniaturized dual-enhancement spectrophone is proposed for high-performance sensing and analysis of trace gases in confined spaces or scenarios with fewer samples. A compact nonresonant photoacoustic cell (PAC) with a volume of 1 mL is employed in conjunction with a distributed feedback (DFB) laser to excite photoacoustic signals. In order to improve the performance of the FOPAS, a Herriott multi pass reflection structure is constructed in the compact PAC based on two concave mirrors which effectively enhances the excitation power. A fiber-optic acoustic sensor (FOAS) with Fabry-Perot (F-P) interference structure is applied to sense the weak photoacoustic signals and the sensitivity of trace gas detection is enhanced by the mechanical resonance enhancement of the silicon cantilever acoustic sensitive element. This dual-enhancement strategy effectively combines multi pass excitation and resonant cantilever amplification, providing a solution to the persistent challenge of maintaining high sensitivity while achieving sensor miniaturization. The all-optical detection scheme employed in this gas sensing system, furthermore, enhances its immunity to electromagnetic interference and broadens its applicability. The experimental results indicate that the minimum detection limit (MDL) of acetylene (C2H2) is 4.5 ppb when the average time is 100 s and the normalized noise equivalent absorption (NNEA) coefficient is $6\times 10^{-{10}}$ ${\mathrm {cm}}^{-{1}}$ ${\mathrm {W/Hz}}^{{1}/{2}}$ .
Förderung
- National Nature Science Foundation of China
- Natural Science Foundation of Zhejiang Province
- Science and Technology Planning Project of Shaoxing City
- Natural Science Foundation of Liaoning Province
- Dalian High-level Talent Innovation Support Plan
Zitieren
APA
Yang, B., Wang, Y., Guo, M., Li, C., Zhao, X., Qi, H., Song, J., Fan, J., Gao, Y., Fang, Z., & Chen, K. (2025). Ultrasensitive Fiber-Optic Photoacoustic Gas Sensor Based on Miniaturized Dual-Enhancement Spectrophone. IEEE Sensors Journal, 25(12), 21464-21472. https://doi.org/10.1109/jsen.2025.3566410
Vancouver
Yang B, Wang Y, Guo M, Li C, Zhao X, Qi H, et al. Ultrasensitive Fiber-Optic Photoacoustic Gas Sensor Based on Miniaturized Dual-Enhancement Spectrophone. IEEE Sensors Journal. 2025;25(12):21464-21472. doi:10.1109/jsen.2025.3566410
BibTeX
@article{Yang2025,
author = {Yang, Beilei and Wang, Yifan and Guo, Min and Li, Chenxi and Zhao, Xinyu and Qi, Hongchao and Song, Jie and Fan, Jiayi and Gao, Yuan and Fang, Zebo and Chen, Ke},
title = {Ultrasensitive Fiber-Optic Photoacoustic Gas Sensor Based on Miniaturized Dual-Enhancement Spectrophone},
journal = {IEEE Sensors Journal},
year = {2025},
volume = {25},
number = {12},
pages = {21464--21472},
doi = {10.1109/jsen.2025.3566410}
}
EUVIMED