EUVIMEDEUVIMED entdecken
Crossref

Highly Sensitive Flow Cytometry Biosensor with a High Signal-to-Background Ratio for FEN1 Analysis via Solid-Phase Interface-Mediated Primer Exchange Reaction Amplification

Yong-Li Song, Xiang-Lan He, Yarong Guo, Li-Yun Ma, Ming Jiang iD, Li Xu iD, Xu Yu iD, Qi Mei

Analytical Chemistry · 2025

DOI: 10.1021/acs.analchem.4c04564 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, 2025. Verfasst von Yong-Li Song und 7 weiteren Autor:innen. Beteiligte Einrichtung: Tongji School of Pharmacy, Huazhong University of Science and Technology, Wuhan 430030, China. Hauptthemen laut MEDLINE: Flap Endonucleases, Biosensing Techniques, Flow Cytometry, Nucleic Acid Amplification Techniques. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: Huazhong University of Science and Technology, Natural Science Foundation of Hubei Province, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Flap endonuclease 1 (FEN1) is a specific enzyme capable of recognizing and cleaving triplex DNA structures and releasing 5'-flap fragments. It plays a crucial role in the DNA metabolism of cells, participating in DNA replication and the repair of damaged DNA. Additionally, FEN1 is overexpressed in various tumor tissues, promoting tumor progression and drug resistance through different regulatory mechanisms. However, few significant advancements have been made in sensitive analytical methods for detecting FEN1. Herein, in this study, we present a highly sensitive flow cytometry biosensor with solid-phase interface-mediated primer exchange reaction amplification (FCsperA) for FEN1 analysis. By comparing homogeneous PER amplification (h-PER), we found that solid-phase interface-mediated PER amplification (s-PER) effectively suppressed background signals, leading to a higher signal-to-background (S/B) ratio exceeding ∼46-fold when FEN1 was at 1 × 10-3 U/μL. Combining the high efficiency of s-PER, the strong suppression of background signals, and the highly precise flow cytometry assay, FCsperA showed high sensitivity, with a limit of detection (LOD) for FEN1 of 2.53 × 10-6 U/μL. Notably, FCsperA exhibited high selectivity and exceptional anti-interference ability, making it applicable for detecting FEN1 in cells and serum samples. The outstanding performance of FCsperA allowed for sensing FEN1 in ∼10 cancer cells. Additionally, FCsperA demonstrated the potential for screening inhibitors of FEN1.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Flap EndonucleasesBiosensing TechniquesFlow CytometryNucleic Acid Amplification TechniquesHumansLimit of Detection

Substanzen

Flap EndonucleasesFEN1 protein, human

Autor:innen und Institutionen

  • Tongji School of Pharmacy, Huazhong University of Science and Technology, Wuhan 430030, China.
  • Cancer Center, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Third Hospital of Shanxi Medical University, Taiyuan 030032, Shanxi, China.
  • Department of Digestive System Oncology, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Third Hospital of Shanxi Medical University, Taiyuan 030032, Shanxi, China.
  • Department of Pharmacy, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China.
  • Department of Oncology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China.

ORCID-Profile: Ming Jiang, Li Xu, Xu Yu

Förderung

  • Huazhong University of Science and Technology
  • Natural Science Foundation of Hubei Province
  • National Natural Science Foundation of China
  • Shanxi Bethune Hospital

Zitieren

APA

Song, Y. L., He, X. L., Guo, Y., Ma, L. Y., Jiang, M., Xu, L., Yu, X., & Mei, Q. (2025). Highly Sensitive Flow Cytometry Biosensor with a High Signal-to-Background Ratio for FEN1 Analysis via Solid-Phase Interface-Mediated Primer Exchange Reaction Amplification. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.4c04564

Vancouver

Song YL, He XL, Guo Y, Ma LY, Jiang M, Xu L, et al. Highly Sensitive Flow Cytometry Biosensor with a High Signal-to-Background Ratio for FEN1 Analysis via Solid-Phase Interface-Mediated Primer Exchange Reaction Amplification. Analytical Chemistry. 2025. doi:10.1021/acs.analchem.4c04564

BibTeX
@article{Song2025,
  author = {Song, Yong-Li and He, Xiang-Lan and Guo, Yarong and Ma, Li-Yun and Jiang, Ming and Xu, Li and Yu, Xu and Mei, Qi},
  title = {Highly Sensitive Flow Cytometry Biosensor with a High Signal-to-Background Ratio for FEN1 Analysis via Solid-Phase Interface-Mediated Primer Exchange Reaction Amplification},
  journal = {Analytical Chemistry},
  year = {2025},
  doi = {10.1021/acs.analchem.4c04564}
}
Kostenlos starten →