Electrochemical Biosensors for the Detection of Exosomal microRNA Biomarkers for Early Diagnosis of Neurodegenerative Diseases
Analytical Chemistry · 18.03.2025 · 97 (10) · 5355-5371
DOI: 10.1021/acs.analchem.4c02619 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Analytical Chemistry, online erschienen am 09.03.2025. Verfasst von Jiacheng Yu und 10 weiteren Autor:innen. Beteiligte Einrichtung: Biotechnology and Food Engineering, Guangdong Technion-Israel Institute of Technology (GTIIT), Shantou 515063, China. Hauptthemen laut MEDLINE: MicroRNAs, Biosensing Techniques, Electrochemical Techniques, Neurodegenerative Diseases. Die Arbeit wurde bisher 65-mal zitiert (Crossref) und nennt 143 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Basic and Applied Basic Research Foundation of Guangdong Province, Science and Technology Planning Project of Shenzen Municipality, Natural Science Foundation of Guangdong Province.
Abstract (Originalsprache)
Early and precise diagnosis of neurodegenerative disorders like Alzheimer's (AD) and Parkinson's (PD) is crucial for slowing their progression and enhancing patient outcomes. Exosomal microRNAs (miRNAs) are emerging as promising biomarkers due to their ability to reflect the diseases' pathology, yet their low abundance poses significant detection hurdles. This review article delves into the burgeoning field of electrochemical biosensors, designed for the precise detection of exosomal miRNA biomarkers. Electrochemical biosensors offer a compelling solution, combining the sensitivity required to detect low-abundance biomarkers with the specificity needed to discern miRNA profiles distinctive to neural pathological states. We explore the operational principles of these biosensors, including the electrochemical transduction mechanisms that facilitate miRNA detection. The review also summarizes advancements in nanotechnology, signal enhancement, bioreceptor anchoring, and microfluidic integration that improve sensor accuracy. The evidence of their use in neurodegenerative disease diagnosis is analyzed, focusing on the clinical impact, diagnostic precision, and obstacles faced in practical applications. Their potential integration into point-of-care testing and regulatory considerations for their market entry are discussed. Looking toward the future, the article highlights forthcoming innovations that might revolutionize early diagnostic processes. Electrochemical biosensors, with their impressive sensitivity, specificity, and point-of-care compatibility, are on track to become instrumental in the early diagnosis of neurodegenerative diseases, possibly transforming patient care and prognosis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Biotechnology and Food Engineering, Guangdong Technion-Israel Institute of Technology (GTIIT), Shantou 515063, China.
- Faculty of Biotechnology and Food Engineering, Technion-Israel Institute of Technology (IIT), Haifa 3200003, Israel.
- Sichuan Provincial Key Laboratory for Human Disease Gene Study, Department of Medical Genetics, Sichuan Academy of Medical Sciences & Sichuan Provincial People's Hospital, University of Electronic Science and Technology…
- Department of Gastroenterology, The First Medical Center of Chinese PLA General Hospital, Beijing 100853, China.
- School of Medicine, The Chinese University of Hong Kong Shenzhen, Shenzhen 518172, China.
- Guangdong Provincial Key Laboratory of Materials and Technologies for Energy Conversion, Shantou 515063, China.
ORCID-Profile: Jintao Zheng, Ester Segal, Cheng Jiang, Keying Guo
Förderung
- Basic and Applied Basic Research Foundation of Guangdong Province
- Science and Technology Planning Project of Shenzen Municipality
- Natural Science Foundation of Guangdong Province
- Guangdong Province
- Shenzhen Institute of Advanced Technology
Zitieren
APA
Yu, J., Zhou, R., Liu, S., Zheng, J., Yan, H., Su, S., Chai, N., Segal, E., Jiang, C., Guo, K., & Li, C. Z. (2025). Electrochemical Biosensors for the Detection of Exosomal microRNA Biomarkers for Early Diagnosis of Neurodegenerative Diseases. Analytical Chemistry, 97(10), 5355-5371. https://doi.org/10.1021/acs.analchem.4c02619
Vancouver
Yu J, Zhou R, Liu S, Zheng J, Yan H, Su S, et al. Electrochemical Biosensors for the Detection of Exosomal microRNA Biomarkers for Early Diagnosis of Neurodegenerative Diseases. Analytical Chemistry. 2025;97(10):5355-5371. doi:10.1021/acs.analchem.4c02619
BibTeX
@article{Yu2025,
author = {Yu, Jiacheng and Zhou, Runzhi and Liu, Shan and Zheng, Jintao and Yan, Haoyang and Su, Song and Chai, Ningli and Segal, Ester and Jiang, Cheng and Guo, Keying and Li, Chen-Zhong},
title = {Electrochemical Biosensors for the Detection of Exosomal microRNA Biomarkers for Early Diagnosis of Neurodegenerative Diseases},
journal = {Analytical Chemistry},
year = {2025},
volume = {97},
number = {10},
pages = {5355--5371},
doi = {10.1021/acs.analchem.4c02619}
}
EUVIMED