EUVIMEDEUVIMED entdecken
Crossref

Real-Time Signal Analysis with Wider Dynamic Range and Enhanced Sensitivity in Multiplex Colorimetric Immunoassays Using Encoded Hydrogel Microparticles

Yong Jun Lim iD, Jun Hee Choi, Seok Joon Mun, Jiwoo Kim, Ki Wan Bong iD

Analytical Chemistry · 07.05.2024 · 96 (18) · 7204-7211

DOI: 10.1021/acs.analchem.4c00773 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 25.04.2024. Verfasst von Yong Jun Lim und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical and Biological Engineering, Korea University, Seoul 02841, South Korea. Hauptthemen laut MEDLINE: Colorimetry, Hydrogels. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: Ministry of Science and ICT, South Korea, Ministry of Trade, Industry and Energy, Ministry of Science, ICT and Future Planning.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The simultaneous quantification of multiple proteins is crucial for accurate medical diagnostics. A promising technology, the multiplex colorimetric immunoassay using encoded hydrogel microparticles, has garnered attention, due to its simplicity and multiplex capabilities. However, it encounters challenges related to its dynamic range, as it relies solely on the colorimetric signal analysis of encoded hydrogel microparticles at the specific time point (i.e., end-point analysis). This necessitates the precise determination of the optimal time point for the termination of the colorimetric reaction. In this study, we introduce real-time signal analysis to quantify proteins by observing the continuous colorimetric signal change within the encoded hydrogel microparticles. Real-time signal analysis measures the "slope", the rate of the colorimetric signal generation, by focusing on the kinetics of the accumulation of colorimetric products instead of the colorimetric signal that appears at the end point. By developing a deep learning-based automatic analysis program that automatically reads the code of the graphically encoded hydrogel microparticles and obtains the slope by continuously tracking the colorimetric signal, we achieved high accuracy and high throughput analysis. This technology has secured a dynamic range more than twice as wide as that of the conventional end-point signal analysis, simultaneously achieving a sensitivity that is 4-10 times higher. Finally, as a demonstration of application, we performed multiplex colorimetric immunoassays using real-time signal analysis covering a wide concentration range of protein targets associated with pre-eclampsia.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ColorimetryHydrogelsImmunoassayHumansFemalePregnancyPre-EclampsiaDeep Learning

Substanzen

Hydrogels

Autor:innen und Institutionen

  • Department of Chemical and Biological Engineering, Korea University, Seoul 02841, South Korea.

ORCID-Profile: Yong Jun Lim, Ki Wan Bong

Förderung

  • Ministry of Science and ICT, South Korea
  • Ministry of Trade, Industry and Energy
  • Ministry of Science, ICT and Future Planning

Zitieren

APA

Lim, Y. J., Choi, J. H., Mun, S. J., Kim, J., & Bong, K. W. (2024). Real-Time Signal Analysis with Wider Dynamic Range and Enhanced Sensitivity in Multiplex Colorimetric Immunoassays Using Encoded Hydrogel Microparticles. Analytical Chemistry, 96(18), 7204-7211. https://doi.org/10.1021/acs.analchem.4c00773

Vancouver

Lim YJ, Choi JH, Mun SJ, Kim J, Bong KW. Real-Time Signal Analysis with Wider Dynamic Range and Enhanced Sensitivity in Multiplex Colorimetric Immunoassays Using Encoded Hydrogel Microparticles. Analytical Chemistry. 2024;96(18):7204-7211. doi:10.1021/acs.analchem.4c00773

BibTeX
@article{Lim2024,
  author = {Lim, Yong Jun and Choi, Jun Hee and Mun, Seok Joon and Kim, Jiwoo and Bong, Ki Wan},
  title = {Real-Time Signal Analysis with Wider Dynamic Range and Enhanced Sensitivity in Multiplex Colorimetric Immunoassays Using Encoded Hydrogel Microparticles},
  journal = {Analytical Chemistry},
  year = {2024},
  volume = {96},
  number = {18},
  pages = {7204--7211},
  doi = {10.1021/acs.analchem.4c00773}
}
Kostenlos starten →