Colorimetric/chemiluminescent vertical flow immunoassay based on multifunctional cobalt–gold bimetallic nanoclusters for Brucella antibody detection and deep learning-assisted semiquantitative analysis
Microchimica Acta · 2026
DOI: 10.1007/s00604-026-08444-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchimica Acta, 2026. Verfasst von Hamai Bi und 12 weiteren Autor:innen. Beteiligte Einrichtung: College of Life Sciences, Shihezi University, 832003, Shihezi, China. Hauptthemen laut MEDLINE: Colorimetry, Metal Nanoparticles, Antibodies, Bacterial, Deep Learning. Die Arbeit nennt 34 Literaturangaben. Gefördert von: "Tianshan Talents"Training Program, Basic Research and Public Welfare Special Project of lli Kazakh Autonomous Prefecture Science and Technology Plan, Research Project of Xinjiang Uygur Autonomous Region Health Commission.
Abstract (Originalsprache)
A colorimetric/chemiluminescent vertical flow immunoassay (VFI) for Brucellosis was developed using glutathione-protected cobalt-gold nanoclusters conjugated with staphylococcal protein A (GSH@Co-AuNCs-SPA) as multifunctional catalytic immunoprobes. The nanocluster probe integrates antibody recognition with peroxidase-like catalytic activity, enabling three complementary signal readouts within a common immunorecognition architecture: direct colorimetric visualization, TMB-H₂O₂-amplified colorimetry, and luminol-H₂O₂ chemiluminescence.The prepared GSH@Co-AuNCs exhibited H₂O₂-mediated catalytic activity and sustained chemiluminescent emission, with a detectable visual signal persisting for more than 150 min, thereby providing a broad acquisition window for low-background imaging. Serial-dilution experiments showed experimentally determined signal-discrimination thresholds of 0.5 IU mL⁻¹ for direct colorimetry and 0.2 IU mL⁻¹ for both TMB-amplified colorimetry and chemiluminescence. For the chemiluminescent mode, analysis of 20 independent blank measurements yielded a statistical limit of detection of 0.134 IU mL⁻¹. Under the same analytical dilution-series conditions, a commercial colloidal-gold lateral-flow assay produced a visually distinguishable signal down to 20 IU mL⁻¹.To improve the consistency of image interpretation, shared-weight dual-branch ResNet-18 regression models were established for both TMB and chemiluminescent images. Grouped five-fold cross-validation yielded mean R² values of 0.8746 ± 0.0784 and 0.8907 ± 0.0588, with four-level grading accuracies of 96.25 ± 2.10% and 93.00 ± 6.28% for the TMB and chemiluminescent models, respectively. In a preliminary evaluation of 30 clinical serum samples, TMB-amplified colorimetry showed 95.0% sensitivity, 90.0% specificity, and 93.3% overall agreement with the serum agglutination test (SAT), whereas chemiluminescence showed 95.0%, 100%, and 96.7%, respectively.The proposed platform integrates catalytic signal amplification, complementary optical readouts, and regression-based semiquantitative interpretation within a single VFI system. This strategy provides a practical framework for improving weak-signal discrimination and standardized interpretation in rapid anti-Brucella antibody screening, while further validation in larger independent clinical cohorts remains necessary.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- College of Life Sciences, Shihezi University, 832003, Shihezi, China.
- The First Division Hospital of Xinjiang Production and Construction Corps, Department of Blood Transfusion , 843000, Aksu, China.
- The Friendship Hospital of Ili Kazakh Autonomous Prefecture, 835000, Yining, Xinjiang Uygur Autonomous Region, China. yalijiang@njmu.edu.cn.
- College of Life Sciences, Shihezi University, 832003, Shihezi, China. shifeng2314@yeah.net.
Förderung
- "Tianshan Talents"Training Program
- Basic Research and Public Welfare Special Project of lli Kazakh Autonomous Prefecture Science and Technology Plan
- Research Project of Xinjiang Uygur Autonomous Region Health Commission
Zitieren
APA
Bi, H., Zhao, X., Wei, M., Li, X., Wu, J., Wang, Y., Zhang, X., Ma, H., Zhou, H., Xu, Z., Guo, K., Jiang, Y., & Shi, F. (2026). Colorimetric/chemiluminescent vertical flow immunoassay based on multifunctional cobalt–gold bimetallic nanoclusters for Brucella antibody detection and deep learning-assisted semiquantitative analysis. Microchimica Acta. https://doi.org/10.1007/s00604-026-08444-2
Vancouver
Bi H, Zhao X, Wei M, Li X, Wu J, Wang Y, et al. Colorimetric/chemiluminescent vertical flow immunoassay based on multifunctional cobalt–gold bimetallic nanoclusters for Brucella antibody detection and deep learning-assisted semiquantitative analysis. Microchimica Acta. 2026. doi:10.1007/s00604-026-08444-2
BibTeX
@article{Bi2026,
author = {Bi, Hamai and Zhao, Xiaogang and Wei, Mingjie and Li, Xia and Wu, Jiahui and Wang, Yuankun and Zhang, Xindi and Ma, Halifei and Zhou, Hengxuan and Xu, Zhihua and Guo, Kedong and Jiang, Yali and Shi, Feng},
title = {Colorimetric/chemiluminescent vertical flow immunoassay based on multifunctional cobalt–gold bimetallic nanoclusters for Brucella antibody detection and deep learning-assisted semiquantitative analysis},
journal = {Microchimica Acta},
year = {2026},
doi = {10.1007/s00604-026-08444-2}
}
EUVIMED