Ultrasensitive Ratiometric Electrochemiluminescence Sensor with an Efficient Antifouling and Antibacterial Interface of PSBMA@SiO 2 -MXene for Oxytetracycline Trace Detection in the Marine Environment

Mengli Ding, Shulei Zhang, Jinge Wang, Yan Ding, Caifeng Ding iD

Analytical Chemistry · 07.11.2023 · 95 (44) · 16327-16334

DOI: 10.1021/acs.analchem.3c03555 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 27.10.2023. Verfasst von Mengli Ding und 4 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, Ministry of Education; Shandong Key Laboratory of Biochemical Ana…. Hauptthemen laut MEDLINE: Oxytetracycline, Biofouling, Biosensing Techniques. Die Arbeit wurde bisher 62-mal zitiert (Crossref) und nennt 48 Literaturangaben. Gefördert von: Major Scientific and Technological Innovation Project of Shandong Province, National Natural Science Foundation of China, Natural Science Foundation of Shandong Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The sensitivity and accuracy of electrochemiluminescence (ECL) sensors for detecting small-molecule pollutants in environmental water are affected not only by nonspecific adsorption of proteins and other molecules but also by bacterial interference. Therefore, there is an urgent need to develop an ECL sensor with antifouling and antibacterial functions for water environment monitoring. Herein, a highly efficient antifouling sensing interface (PSBMA@SiO2-MXene) based on zwitterionic sulfobetaine methacrylate (SBMA) antifouling nanospheres (NPs) and two-dimensional MXene nanosheets was designed for the sensitive detection of oxytetracycline (OTC), an antibiotic small-molecule pollutant. Specifically, SBMA with good hydrophilicity and electrical neutrality was connected to SiO2 NPs, thus effectively reducing protein and bacterial adsorption and improving stability. Second, MXene with a high specific surface area was selected as the carrier to load more antifouling NPs, which greatly improves the antifouling performance. Meanwhile, the introduction of MXene also enhances the conductivity of the antifouling interface. In addition, a ratio-based sensing strategy was designed to further improve the detection accuracy and sensitivity of the sensor by utilizing Au@luminol as an internal standard factor. Based on antifouling and antibacterial interfaces, as well as internal standard and ratiometric sensing strategies, the detection range of the proposed sensor was 0.1 ng/mL to 100 μg/mL, with a detection limit of 0.023 ng/mL, achieving trace dynamic monitoring of antibiotics in complex aqueous media.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

OxytetracyclineBiofoulingBiosensing TechniquesSilicon DioxideAnti-Bacterial AgentsWaterElectrochemical TechniquesNitritesTransition Elements

Substanzen

OxytetracyclineSilicon DioxideAnti-Bacterial AgentsWaterMXeneNitritesTransition Elements

Autor:innen und Institutionen

  • Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, Ministry of Education; Shandong Key Laboratory of Biochemical Analysis; Key Laboratory of Analytical Chemistry for Life Science in Univ…

ORCID-Profile: Caifeng Ding

Förderung

  • Major Scientific and Technological Innovation Project of Shandong Province
  • National Natural Science Foundation of China
  • Natural Science Foundation of Shandong Province

Zitieren

APA

Ding, M., Zhang, S., Wang, J., Ding, Y., & Ding, C. (2023). Ultrasensitive Ratiometric Electrochemiluminescence Sensor with an Efficient Antifouling and Antibacterial Interface of PSBMA@SiO 2 -MXene for Oxytetracycline Trace Detection in the Marine Environment. Analytical Chemistry, 95(44), 16327-16334. https://doi.org/10.1021/acs.analchem.3c03555

Vancouver

Ding M, Zhang S, Wang J, Ding Y, Ding C. Ultrasensitive Ratiometric Electrochemiluminescence Sensor with an Efficient Antifouling and Antibacterial Interface of PSBMA@SiO 2 -MXene for Oxytetracycline Trace Detection in the Marine Environment. Analytical Chemistry. 2023;95(44):16327-16334. doi:10.1021/acs.analchem.3c03555

BibTeX
@article{Ding2023,
  author = {Ding, Mengli and Zhang, Shulei and Wang, Jinge and Ding, Yan and Ding, Caifeng},
  title = {Ultrasensitive Ratiometric Electrochemiluminescence Sensor with an Efficient Antifouling and Antibacterial Interface of PSBMA@SiO 2 -MXene for Oxytetracycline Trace Detection in the Marine Environment},
  journal = {Analytical Chemistry},