Photocurrent polarity switching photoelectrochemical aptasensor for oxytetracycline based on BiOBr/Ag2S/PDA//CuO: CuO-induced II-type to dual Z-scheme system
Analytica Chimica Acta · 2024
DOI: 10.1016/j.aca.2024.342920 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024. Verfasst von Rumeng Song und 4 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry, Green Catalysis Center, Zhengzhou University, PR China. Hauptthemen laut MEDLINE: Oxytetracycline, Copper, Aptamers, Nucleotide, Electrochemical Techniques. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 53 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
BACKGROUND: As a broad-spectrum tetracycline antibiotic, Oxytetracycline (OTC) was widely used in a variety of applications. But, the overuse of OTC had led to the detection of it in food, water and soil, which could present significance risk to human health and cause damage to ecosystem. It was of great significance to develop sensitive detection methods for OTC. Herein, an environmentally friendly photoelectrochemical (PEC) aptasensor was constructed for the sensitive detection of OTC based on CuO-induced BiOBr/Ag2S/PDA (Polydopamine) photocurrent polarity reversal. RESULTS: BiOBr/Ag2S/PDA composites modified electrode not only produced stable initial anodic photocurrent but also provided attachment sites for the aptamer S1 of OTC by the strong adhesion of PDA. On the other hand, CuO loaded OTC aptamer S2 (Cu-S2) was got through Cu-S bonds. After the target OTC was identified on the electrode surface, CuO was introduced to the surface of ITO/BiOBr/Ag2S/PDA through the specific binding of OTC to S2. This identification process formed dual Z-type heterojunctions and resulted in a remarkable reversal of photocurrent polarity from anodic to cathodic. Under optimization conditions, the PEC aptasensor showed a wide linear range (50 fM ∼ 100 nM), low detection limit (1.9 fM), excellent selectivity, stability and reproducibility for the detection of OTC. Moreover, it was successfully used for the analysis of OTC in real samples of tap water, milk and honey, and had the potential for practical application. SIGNIFICANCE: This work developed an environmentally friendly photocurrent-polarity-switching PEC aptasensor with excellent selectivity, reproducibility, stability, low LOD and wide linear range for OTC detection. This sensitive system, which was including BiOBr, Ag2S, PDA and CuO were low toxicity, not only reduced the risk of traditional toxic semiconductors to operators and the environment, but can also be used for the detection of real samples, broadening the wider range of applications for BiOBr, Ag2S, PDA and CuO.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- College of Chemistry, Green Catalysis Center, Zhengzhou University, PR China.
- Department of Orthopedics, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450001, PR China.
- College of Chemistry, Green Catalysis Center, Zhengzhou University, PR China. Electronic address: zoulina@zzu.edu.cn.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Song, R., Wang, R., Zhang, C., Li, G., & Zou, L. (2024). Photocurrent polarity switching photoelectrochemical aptasensor for oxytetracycline based on BiOBr/Ag2S/PDA//CuO: CuO-induced II-type to dual Z-scheme system. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2024.342920
Vancouver
Song R, Wang R, Zhang C, Li G, Zou L. Photocurrent polarity switching photoelectrochemical aptasensor for oxytetracycline based on BiOBr/Ag2S/PDA//CuO: CuO-induced II-type to dual Z-scheme system. Analytica Chimica Acta. 2024. doi:10.1016/j.aca.2024.342920
BibTeX
@article{Song2024,
author = {Song, Rumeng and Wang, Ruoyu and Zhang, Chi and Li, Gaiping and Zou, Lina},
title = {Photocurrent polarity switching photoelectrochemical aptasensor for oxytetracycline based on BiOBr/Ag2S/PDA//CuO: CuO-induced II-type to dual Z-scheme system},
journal = {Analytica Chimica Acta},
year = {2024},
doi = {10.1016/j.aca.2024.342920}
}
EUVIMED