High-Sensitivity, Low-Field 19 F-MRI Approach Using High Manganese Ferrite Concentrations
Analytical Chemistry · 2023
DOI: 10.1021/acs.analchem.3c00379 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, 2023. Verfasst von Yupeng Cao und 5 weiteren Autor:innen. Beteiligte Einrichtung: National Center for Nanoscience and Technology, Beijing 100190, China. Hauptthemen laut MEDLINE: Fluorine, Fluorocarbons. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 30 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Chinese Academy of Sciences.
Abstract (Originalsprache)
Fluorine-19 (19F) MRI (19F-MRI) is a promising method for quantifying biomedical research and clinical applications without background interference. Nevertheless, dependency on high-field MRI systems limits the applicability of 19F-MRI. Low-field MRI systems are more common than high-field MRI systems. Hence, developing 19F-MRI at low-field MRI devices can promote the 19F-MRI translation in medical diagnosis. The detection sensitivity of fluorine agents is critical in 19F-MRI. Reduction of the 19F spin-lattice relaxation time (T1) enables an improved detection sensitivity while requiring ultrashort echo time (UTE) imaging methods to reduce the negative spin-spin relaxation (T2) decay effect. However, conventional UTE sequences require hardware with high performance. Herein, we introduce the k-space scaling imaging (KSSI) MRI sequence that accomplishes sampling k-space with variable scales to implement hardware-friendly UTE 19F-MRI compatible with low-field MRI systems. We implemented experiments with swine bone, a perfluorooctyl bromide (PFOB) phantom, and one tumor-bearing mouse on two self-customized low-field MRI systems. The swine bone imaging validated the ultrashort TE of KSSI. Under high concentrations of manganese ferrite, a high signal-to-noise ratio was shown in the imaging of a fluorine atom concentration of 658 mM, which indicated high-sensitivity detection of KSSI. Moreover, the KSSI sequence exhibited a 7.1 times signal-to-noise ratio of spin echo sequence on the PFOB phantom imaging with a fluorine atom concentration of 3.29 M. Additionally, the various concentrations of the PFOB phantom imaging revealed quantifiable capacity. Finally, the 1H/19F imaging was implemented with KSSI on one tumor-bearing mouse. This method provides the potential for clinical translation of fluorine probes at low-field MRI systems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- National Center for Nanoscience and Technology, Beijing 100190, China.
- School of Future Technology, University of Chinese Academy of Sciences, Beijing 100049, China.
- Institute of Regenerative and Reconstructive Medicine, Med-X Institute, First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi 710049, China.
- State Key Laboratory of Biochemical Engineering, Institute of Process Engineering, Chinese Academy of Sciences, Beijing 100190, China.
ORCID-Profile: Yupeng Cao, Xiaohan Zhou, Xiaoli Liu, Wentao Liu, Dong Han
Förderung
- National Natural Science Foundation of China
- Chinese Academy of Sciences
Zitieren
APA
Cao, Y., Zhou, X., Liu, X., Yang, M., Liu, W., & Han, D. (2023). High-Sensitivity, Low-Field 19 F-MRI Approach Using High Manganese Ferrite Concentrations. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.3c00379
Vancouver
Cao Y, Zhou X, Liu X, Yang M, Liu W, Han D. High-Sensitivity, Low-Field 19 F-MRI Approach Using High Manganese Ferrite Concentrations. Analytical Chemistry. 2023. doi:10.1021/acs.analchem.3c00379
BibTeX
@article{Cao2023,
author = {Cao, Yupeng and Zhou, Xiaohan and Liu, Xiaoli and Yang, Mei and Liu, Wentao and Han, Dong},
title = {High-Sensitivity, Low-Field 19 F-MRI Approach Using High Manganese Ferrite Concentrations},
journal = {Analytical Chemistry},
year = {2023},
doi = {10.1021/acs.analchem.3c00379}
}
EUVIMED