Human-in-the-loop optimization of wearable device parameters using an EMG-based objective function
Wearable Technologies · 2024 · 5
DOI: 10.1017/wtc.2024.9 ↗Kurz gefasst
Fachartikel in der Zeitschrift Wearable Technologies, online erschienen am 22.11.2024. Verfasst von María Alejandra Díaz und 5 weiteren Autor:innen. Beteiligte Einrichtung: BruBotics, Vrije Universiteit Brussel, Brussels, 1050, Belgium. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Advancements in wearable robots aim to improve user motion, motor control, and overall experience by minimizing energetic cost (EC). However, EC is challenging to measure and it is typically indirectly estimated through respiratory gas analysis. This study introduces a novel EMG-based objective function that captures individuals’ natural energetic expenditure during walking. The objective function combines information from electromyography (EMG) variables such as intensity and muscle synergies. First, we demonstrate the similarity of the proposed objective function, calculated offline, to the EC during walking. Second, we minimize and validate the EMG-based objective function using an online Bayesian optimization algorithm. The walking step frequency is chosen as the parameter to optimize in both offline and online approaches in order to simplify experiments and facilitate comparisons with related research. Compared to existing studies that use EC as the objective function, results demonstrated that the optimization of the presented objective function reduced the number of iterations and, when compared with gradient descent optimization strategies, also reduced convergence time. Moreover, the algorithm effectively converges toward an optimal step frequency near the user’s preferred frequency, positively influencing EC reduction. The good correlation between the estimated objective function and measured EC highlights its consistency and reliability. Thus, the proposed objective function could potentially optimize lower limb exoskeleton assistance and improve user performance and human–robot interaction without the need for challenging respiratory gas measurements.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- BruBotics, Vrije Universiteit Brussel, Brussels, 1050, Belgium.
- Human Physiology and Sports Physiotherapy Research Group, Vrije Universiteit Brussel, Brussels, 1050, Belgium.
- Institute of Autonomous Systems and Mechatronics, Department of Electrical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, 91052, Germany.
- Department of Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, 91052, Germany.
- Laboratory for Neuromechanics and Biorobotics, Department of Automation, Biocybernetics and Robotics, Jožef Stefan Institute, Ljubljana, 1000, Slovenia.
- Faculty of Electrical Engineering, University of Ljubljana, Ljubljana, 1000, Slovenia.
ORCID-Profile: María Alejandra Díaz, Sander De Bock, Philipp Beckerle, Jan Babič, Tom Verstraten
Zitieren
APA
Díaz, M. A., De Bock, S., Beckerle, P., Babič, J., Verstraten, T., & De Pauw, K. (2024). Human-in-the-loop optimization of wearable device parameters using an EMG-based objective function. Wearable Technologies, 5. https://doi.org/10.1017/wtc.2024.9
Vancouver
Díaz MA, De Bock S, Beckerle P, Babič J, Verstraten T, De Pauw K. Human-in-the-loop optimization of wearable device parameters using an EMG-based objective function. Wearable Technologies. 2024;5. doi:10.1017/wtc.2024.9
BibTeX
@article{Daz2024,
author = {Díaz, María Alejandra and De Bock, Sander and Beckerle, Philipp and Babič, Jan and Verstraten, Tom and De Pauw, Kevin},
title = {Human-in-the-loop optimization of wearable device parameters using an EMG-based objective function},
journal = {Wearable Technologies},
year = {2024},
volume = {5},
doi = {10.1017/wtc.2024.9}
}
EUVIMED