Design and evaluation of the pneumatic leg prosthesis ERiK to assist elderly amputees with sit-down and stand-up movements
Wearable Technologies · 2023 · 4
DOI: 10.1017/wtc.2023.8 ↗Kurz gefasst
Fachartikel in der Zeitschrift Wearable Technologies, online erschienen am 26.05.2023. Verfasst von Heike Vallery und 4 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Mechanical, Maritime and Materials Engineering, TU Delft, Delft, The Netherlands. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Standing up using one leg is a challenging task for those with a transfemoral amputation, particularly for elderly users with a low activity level. Active prostheses are generally not accessible to this group and available passive prostheses do not support standing up. This article presents the design and evaluation of the “Energy Restoring Intelligent Knee” (ERiK), which stores energy during sit-down in a pneumatic cylinder and returns it during stand-up. We hypothesized that the system would reduce the time needed to perform transitions and also enable higher load sharing by the prosthetic leg. However, the results of an experimental study with seven participants with transfemoral amputation contradict these hypotheses: the participants could neither move faster nor make more use of the prosthetic leg to share their body weight during transitions. We observed that a major obstacle to the useful functionality of the leg was the absence of ankle dorsiflexion – the foot tended to slip during stand-up initiation, such that only low pre-pressures and therefore support levels could be set. The rather binary action of the pneumatics also complicated movement initiation. The lessons learned from this study may be helpful to those seeking to create better designs in the future.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Mechanical, Maritime and Materials Engineering, TU Delft, Delft, The Netherlands.
- Department of Rehabilitation Medicine, Erasmus MC, Rotterdam, The Netherlands.
ORCID-Profile: Heike Vallery, Gerwin Smit
Zitieren
APA
Vallery, H., Lachmann, F., van der Helm, S., Pennycott, A., & Smit, G. (2023). Design and evaluation of the pneumatic leg prosthesis ERiK to assist elderly amputees with sit-down and stand-up movements. Wearable Technologies, 4. https://doi.org/10.1017/wtc.2023.8
Vancouver
Vallery H, Lachmann F, van der Helm S, Pennycott A, Smit G. Design and evaluation of the pneumatic leg prosthesis ERiK to assist elderly amputees with sit-down and stand-up movements. Wearable Technologies. 2023;4. doi:10.1017/wtc.2023.8
BibTeX
@article{Vallery2023,
author = {Vallery, Heike and Lachmann, Frederik and van der Helm, Simon and Pennycott, Andrew and Smit, Gerwin},
title = {Design and evaluation of the pneumatic leg prosthesis ERiK to assist elderly amputees with sit-down and stand-up movements},
journal = {Wearable Technologies},
year = {2023},
volume = {4},
doi = {10.1017/wtc.2023.8}
}