EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Estimating ground reaction force with novel carbon nanotube-based textile insole pressure sensors

Kaleb Burch iD, Sagar Doshi iD, Amit Chaudhari iD, Erik Thostenson iD, Jill Higginson iD

Wearable Technologies · 2023 · 4

DOI: 10.1017/wtc.2023.2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Wearable Technologies, online erschienen am 02.03.2023. Verfasst von Kaleb Burch und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, University of Delaware, Newark, DE, USA. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIGMS NIH HHS, National Institute of General Medical Sciences, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study presents a new wearable insole pressure sensor (IPS), composed of fabric coated in a carbon nanotube-based composite thin film, and validates its use for quantifying ground reaction forces (GRFs) during human walking. Healthy young adults ( n = 7) walked on a treadmill at three different speeds while data were recorded simultaneously from the IPS and a force plate (FP). The IPS was compared against the FP by evaluating differences between the two instruments under two different assessments: (1) comparing the two peak forces at weight acceptance and push-off (2PK) and (2) comparing the absolute maximum (MAX) of each gait cycle. Agreement between the two systems was evaluated using the Bland–Altman method. For the 2PK assessment, the group mean of differences (MoD) was −1.3 ± 4.3% body weight (BW) and the distance between the MoD and the limits of agreement (2S) was 25.4 ± 11.1% BW. For the MAX assessment, the average MoD across subjects was 1.9 ± 3.0% BW, and 2S was 15.8 ± 9.3% BW. The results of this study show that this sensor technology can be used to obtain accurate measurements of peak walking forces with a basic calibration and consequently open new opportunities to monitor GRF outside of the laboratory.

Schlagwörter

Stichwörter der Autor:innen

biomechanicsbiomechatronicsembedded electronicsmonitorssensors

Autor:innen und Institutionen

  • Department of Mechanical Engineering, University of Delaware, Newark, DE, USA.

ORCID-Profile: Kaleb Burch, Sagar Doshi, Amit Chaudhari, Erik Thostenson, Jill Higginson

Förderung

  • NIGMS NIH HHS
  • National Institute of General Medical Sciences
  • National Institutes of Health
  • Delaware IDeA Network of Biomedical Research Excellence

Zitieren

APA

Burch, K., Doshi, S., Chaudhari, A., Thostenson, E., & Higginson, J. (2023). Estimating ground reaction force with novel carbon nanotube-based textile insole pressure sensors. Wearable Technologies, 4. https://doi.org/10.1017/wtc.2023.2

Vancouver

Burch K, Doshi S, Chaudhari A, Thostenson E, Higginson J. Estimating ground reaction force with novel carbon nanotube-based textile insole pressure sensors. Wearable Technologies. 2023;4. doi:10.1017/wtc.2023.2

BibTeX
@article{Burch2023,
  author = {Burch, Kaleb and Doshi, Sagar and Chaudhari, Amit and Thostenson, Erik and Higginson, Jill},
  title = {Estimating ground reaction force with novel carbon nanotube-based textile insole pressure sensors},
  journal = {Wearable Technologies},
  year = {2023},
  volume = {4},
  doi = {10.1017/wtc.2023.2}
}
Kostenlos starten →