Design and characterization of hollow microneedles for localized intrascleral drug delivery of ocular formulations
Methods · 2025
DOI: 10.1016/j.ymeth.2024.12.004 ↗Kurz gefasst
Fachartikel in der Zeitschrift Methods, 2025. Verfasst von Shilpkala Gade und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Pharmacy, Queen's University Belfast, Medical Biology Centre, Belfast, UK. Electronic address: sgade01@qub.ac.uk. Hauptthemen laut MEDLINE: Sclera, Drug Delivery Systems, Needles, Microinjections. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Horizon 2020 Framework Programme, Horizon 2020, HORIZON EUROPE Marie Sklodowska-Curie Actions.
Abstract (Originalsprache)
Effective drug delivery to the posterior segment of the eye remains a challenge owing to the limitations of conventional methods such as intravitreal injections, which are associated with significant side effects. This study explored the use of hollow microneedles (HMNs) for localized intrascleral drug delivery as a minimally invasive alternative. Stainless steel HMNs with bevel angles of 30°, 45°, 60°, and 75° were fabricated using wire electron discharge machining. The penetration force of these HMNs in ex vivo porcine sclera was assessed using a texture analyser, revealing that the 60° bevel angle required the lowest force (
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, Belfast, UK. Electronic address: sgade01@qub.ac.uk.
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, Belfast, UK. Electronic address: L.vora@qub.ac.uk.
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, Belfast, UK. Electronic address: r.thakur@qub.ac.uk.
Förderung
- Horizon 2020 Framework Programme
- Horizon 2020
- HORIZON EUROPE Marie Sklodowska-Curie Actions
Zitieren
APA
Gade, S., Vora, L. K., & Thakur, R. R. S. (2025). Design and characterization of hollow microneedles for localized intrascleral drug delivery of ocular formulations. Methods. https://doi.org/10.1016/j.ymeth.2024.12.004
Vancouver
Gade S, Vora LK, Thakur RRS. Design and characterization of hollow microneedles for localized intrascleral drug delivery of ocular formulations. Methods. 2025. doi:10.1016/j.ymeth.2024.12.004
BibTeX
@article{Gade2025,
author = {Gade, Shilpkala and Vora, Lalitkumar K and Thakur, Raghu Raj Singh},
title = {Design and characterization of hollow microneedles for localized intrascleral drug delivery of ocular formulations},
journal = {Methods},
year = {2025},
doi = {10.1016/j.ymeth.2024.12.004}
}
EUVIMED