Bilaterally Aligned Electroosmotic Flow Generated by Porous Microneedle Device for Dual‐Mode Delivery
Advanced Healthcare Materials · 2024
DOI: 10.1002/adhm.202401181 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Healthcare Materials, 2024. Verfasst von Gaobo Wang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Finemechanics, Graduate School of Engineering, Tohoku University, 6-6-1 Aramaki Aoba, Aoba-ku, Sendai, 980-8579, Japan. Hauptthemen laut MEDLINE: Needles, Electroosmosis, Rhodamines. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Tohoku University Frontier Research program (FRiD), Ministry of Education, Culture, Sports, Science and Technology.
Abstract (Originalsprache)
Here, a novel porous microneedle (PMN) device with bilaterally aligned electroosmotic flow (EOF) enabling controllable dual‐mode delivery of molecules is developed. The PMNs placed at anode and cathode compartments are modified with anionic poly‐2‐acrylamido‐2‐methyl‐1‐propanesulfonic acid and cationic poly‐(3‐acrylamidopropyl) trimethylammonium, respectively. The direction of EOF generated by PMN at the cathode compartment is, therefore, reversed from cathode to anode, countering the unwanted cathodal suctioning of interstitial fluid caused by reverse iontophoresis. With the bilateral alignment of EOF, the versatility of the proposed device is evaluated by delivering molecules with different charges and sizes using Franz cell. In addition, a 3D printed probe device is developed to ease practical handling and minimize electrical stimulation by integrating two PMNs in closed proximity. Finally, the performance of the integrated probe device is demonstrated by dual delivery of a variety of molecules (methylene blue, rhodamine B, and fluorescein isothiocyanate–dextran) using pig skin and vaccination using mice with delivered ovalbumin.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Finemechanics, Graduate School of Engineering, Tohoku University, 6-6-1 Aramaki Aoba, Aoba-ku, Sendai, 980-8579, Japan.
- Department of Dermatology, Graduate School of Medicine, Tohoku University, 1-1 Seiryo-machi, Aoba-ku, Sendai, 980-8574, Japan.
- Department of Biomedical Engineering, Graduate School of Biomedical Engineering, Tohoku University, 6-6-4 Aramaki Aoba, Aoba-ku, Sendai, 980-8579, Japan.
- Division for the Establishment of Frontier Sciences of the Organization for Advanced Studies, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai, 980-8577, Japan.
ORCID-Profile: Matsuhiko Nishizawa
Förderung
- Tohoku University Frontier Research program (FRiD)
- Ministry of Education, Culture, Sports, Science and Technology
Zitieren
APA
Wang, G., Kato, K., Ichinose, S., Inoue, D., Kobayashi, A., Terui, H., Tottori, S., Kanzaki, M., & Nishizawa, M. (2024). Bilaterally Aligned Electroosmotic Flow Generated by Porous Microneedle Device for Dual‐Mode Delivery. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.202401181
Vancouver
Wang G, Kato K, Ichinose S, Inoue D, Kobayashi A, Terui H, et al. Bilaterally Aligned Electroosmotic Flow Generated by Porous Microneedle Device for Dual‐Mode Delivery. Advanced Healthcare Materials. 2024. doi:10.1002/adhm.202401181
BibTeX
@article{Wang2024,
author = {Wang, Gaobo and Kato, Kosuke and Ichinose, Sae and Inoue, Daisuke and Kobayashi, Airi and Terui, Hitoshi and Tottori, Soichiro and Kanzaki, Makoto and Nishizawa, Matsuhiko},
title = {Bilaterally Aligned Electroosmotic Flow Generated by Porous Microneedle Device for Dual‐Mode Delivery},
journal = {Advanced Healthcare Materials},
year = {2024},
doi = {10.1002/adhm.202401181}
}
EUVIMED