Customized Evaluation of Progressive Visual Sensitivity Loss in Geographic Atrophy to Improve the Power of Clinical Trials
Ophthalmology Science · 2025-07 · 5 (4) · 100763
DOI: 10.1016/j.xops.2025.100763 ↗Kurz gefasst
Fachartikel in der Zeitschrift Ophthalmology Science, 2025-07. Verfasst von Abera Saeed und 9 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Apellis Pharmaceuticals Inc, National Health and Medical Research Council, State Government of Victoria.
Abstract (Originalsprache)
Purpose
To evaluate the effectiveness of different approaches for customizing the selection of a subset of test locations on defect-mapping microperimetry (DMP) for improving the detection of progressive visual function decline in geographic atrophy (GA).
Design
Prospective longitudinal study.
Participants
Sixty eyes from 53 participants with GA secondary to age-related macular degeneration.
Methods
Participants underwent 3-monthly DMP testing twice at each visit for up to 24 months, where the extent of deep visual sensitivity losses on each test was determined through single presentations of 10-decibel stimuli at 208 locations within the central 8° radius region. Seven outcome measures were derived, which included evaluating the proportion of locations missed (PLM; showing nonresponse to stimuli) on DMP in a subset of test locations based on their proximity to the GA margin, or to locations neighboring repeatably nonresponding points on 2 baseline tests (i.e., missed both tests at baseline). These outcome measures were compared by their coefficient of variation (CoV; reflecting performance for capturing longitudinal changes) and sample size estimates in a 2-arm trial seeking to detect a ≥30% treatment effect. Changes in GA extent and best-corrected visual acuity (BCVA) were evaluated for comparison. Main Outcome Measures: Coefficient of variation and sample size estimates.
Results
Evaluating PLM at points immediately adjacent (
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia.
- Ophthalmology, Department of Surgery, The University of Melbourne, Melbourne, Australia.
Förderung
- Apellis Pharmaceuticals Inc
- National Health and Medical Research Council
- State Government of Victoria
- BrightFocus Foundation
Zitieren
APA
Saeed, A., Guymer, R. H., Hadoux, X., Jannaud, M., Dang, D., Hodgson, L. A. B., Glover, E. K., Gee, E. E., van Wijngaarden, P., & Wu, Z. (2025). Customized Evaluation of Progressive Visual Sensitivity Loss in Geographic Atrophy to Improve the Power of Clinical Trials. Ophthalmology Science, 5(4), 100763. https://doi.org/10.1016/j.xops.2025.100763
Vancouver
Saeed A, Guymer RH, Hadoux X, Jannaud M, Dang D, Hodgson LAB, et al. Customized Evaluation of Progressive Visual Sensitivity Loss in Geographic Atrophy to Improve the Power of Clinical Trials. Ophthalmology Science. 2025;5(4):100763. doi:10.1016/j.xops.2025.100763
BibTeX
@article{Saeed2025,
author = {Saeed, Abera and Guymer, Robyn H and Hadoux, Xavier and Jannaud, Maxime and Dang, Darvy and Hodgson, Lauren A B and Glover, Emily K and Gee, Erin E and van Wijngaarden, Peter and Wu, Zhichao},
title = {Customized Evaluation of Progressive Visual Sensitivity Loss in Geographic Atrophy to Improve the Power of Clinical Trials},
journal = {Ophthalmology Science},
year = {2025},
volume = {5},
number = {4},
pages = {100763},
doi = {10.1016/j.xops.2025.100763}
}
EUVIMED