The convergent cavopulmonary connection: A novel and efficient configuration of Fontan to accommodate mechanical support
JTCVS Open · 2023-03 · 13 · 320-329
DOI: 10.1016/j.xjon.2022.12.009 ↗Kurz gefasst
Fachartikel in der Zeitschrift JTCVS Open, 2023-03. Verfasst von Pranava Sinha und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Cardiac Surgery, M Health Fairview, University of Minnesota, Minneapolis, Minn. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Objective
The current total cavopulmonary connection Fontan has competing inflows and outflows, creating hemodynamic inefficiencies that contribute to Fontan failure and complicate placement and efficiency of mechanical circulatory support. We propose a novel convergent cavopulmonary connection (CCPC) Fontan design to create a single, converged venous outflow to the pulmonary arteries, thus increasing efficiency and mechanical circulatory support access. We then evaluate the feasibility and hemodynamic performance of the CCPC in various patient sizes using computational fluid dynamic assessments of computer-aided designs.
Methods
Cardiac magnetic resonance imaging data from 12 patients with single ventricle (10 total cavopulmonary connection, 2 Glenn) physiology (body surface area, 0.5-2.0 m2) were segmented to create 3-dimensional replicas of all thoracic structures. Surgically feasible CCPC shapes within constraints of anatomy were created using iterative computational fluid dynamic and clinician input. Designs varied based on superior and inferior vena cava conduit sizes, coronal attachment height, coronal entry angle, and axial entry angle of the superior vena cava to the inferior vena cava. CCPC designs were optimized based on efficiency (indexed power loss), risk of arteriovenous malformations (hepatic flow distribution), and risk of flow stasis (% nonphysiologic wall shear stress).
Results
All CCPC designs met hemodynamic performance thresholds for indexed power loss and hepatic flow distribution. CCPC designs showed improvements in reducing % nonphysiologic wall shear stress and balancing HFD.
Conclusions
CCPC is physiologically and surgically feasible in various patient sizes using validated computational fluid dynamic models. CCPC configuration has analogous indexed power loss, hepatic flow distribution, and % nonphysiologic wall shear stress compared with total cavopulmonary connection, and the single inflow and outflow may ease mechanical circulatory support therapies. Further studies are required for design optimization and mechanical circulatory support institution.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pediatric Cardiac Surgery, M Health Fairview, University of Minnesota, Minneapolis, Minn.
- Sheikh Zayed Institute of Pediatric Surgical Innovation, Children's National Hospital, Washington, DC.
- Department of Mechanical Engineering, Johns Hopkins University, Baltimore, Md.
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Md.
- Division of Cardiology, Children's National Hospital, Washington, DC.
- Division of Pediatric Cardiology, University of Pittsburgh Medical Center, Pittsburgh, Pa.
Zitieren
APA
Sinha, P., Contento, J., Kim, B., Wang, K., Wu, Q., Cleveland, V., Mass, P., Loke, Y. H., Krieger, A., & Olivieri, L. (2023). The convergent cavopulmonary connection: A novel and efficient configuration of Fontan to accommodate mechanical support. JTCVS Open, 13, 320-329. https://doi.org/10.1016/j.xjon.2022.12.009
Vancouver
Sinha P, Contento J, Kim B, Wang K, Wu Q, Cleveland V, et al. The convergent cavopulmonary connection: A novel and efficient configuration of Fontan to accommodate mechanical support. JTCVS Open. 2023;13:320-329. doi:10.1016/j.xjon.2022.12.009
BibTeX
@article{Sinha2023,
author = {Sinha, Pranava and Contento, Jacqueline and Kim, Byeol and Wang, Kevin and Wu, Qiyuan and Cleveland, Vincent and Mass, Paige and Loke, Yue-Hin and Krieger, Axel and Olivieri, Laura},
title = {The convergent cavopulmonary connection: A novel and efficient configuration of Fontan to accommodate mechanical support},
journal = {JTCVS Open},
year = {2023},
volume = {13},
pages = {320--329},
doi = {10.1016/j.xjon.2022.12.009}
}
EUVIMED