Agreement of a veterinary-specific oscillometric noninvasive arterial blood pressure monitor (SunTech Vet30) with invasive arterial blood pressure in anaesthetised horses
Veterinary Anaesthesia and Analgesia · 2026
DOI: 10.1016/j.vaa.2026.101284 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary Anaesthesia and Analgesia, 2026. Verfasst von Eva Zoe Hernández-Magaña und 3 weiteren Autor:innen. Beteiligte Einrichtung: Departamento de Medicina y Cirugía Animal, Facultad de Veterinaria, Universidad Cardenal, Valencia, Spain. Electronic address: eva.hernandezmagana@uc…. Hauptthemen laut MEDLINE: Oscillometry, Blood Pressure Monitors, Blood Pressure Determination, Anesthesia, General. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
OBJECTIVE: To evaluate agreement between a veterinary-specific oscillometric noninvasive arterial blood pressure monitor and invasive arterial blood pressure (IBP) measurements in anaesthetised horses. STUDY DESIGN: Prospective clinical method-comparison study. ANIMALS: A group of 46 horses undergoing general anaesthesia in dorsal recumbency. METHODS: Paired invasive and oscillometric blood pressure measurements were recorded at 15-minute intervals. IBP was measured via a facial artery catheter, and systolic (SAP), diastolic (DAP), and mean arterial pressures (MAP) were recorded. Oscillometric measurements were obtained using a SunTech Vet30 monitor with the cuff positioned at the tail base or distal thoracic limb, according to clinical access, and hydrostatically corrected relative to the IBP transducer level. Agreement was assessed using repeated-measures Bland-Altman analysis, modelling paired differences as oscillometric minus invasive pressure with horse as a random intercept. RESULTS: A total of 311 paired measurements were analysed. Bias was 3.1 mmHg for SAP, -0.4 mmHg for DAP and -4.5 mmHg for MAP. Limits of agreement were -24.6 to 30.8 mmHg for SAP, -24.5 to 23.7 mmHg for DAP and -30.9 to 21.9 mmHg for MAP. Proportional bias was present for DAP and MAP, indicating pressure-dependent differences. Using an IBP MAP of
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Departamento de Medicina y Cirugía Animal, Facultad de Veterinaria, Universidad Cardenal, Valencia, Spain. Electronic address: eva.hernandezmagana@uchceu.es.
- Small Animal Clinic, University of Veterinary Medicine Hannover, Foundation, Hannover, Germany.
- AniCura Valencia Sur Hospital Veterinario, Silla, Valencia, Spain.
- Departamento de Medicina y Cirugía Animal, Facultad de Veterinaria, Universidad Cardenal, Valencia, Spain.
Zitieren
APA
Hernández-Magaña, E. Z., Gutiérrez Bautista, Á. J., Viscasillas, J., & Redondo, J. I. (2026). Agreement of a veterinary-specific oscillometric noninvasive arterial blood pressure monitor (SunTech Vet30) with invasive arterial blood pressure in anaesthetised horses. Veterinary Anaesthesia and Analgesia. https://doi.org/10.1016/j.vaa.2026.101284
Vancouver
Hernández-Magaña EZ, Gutiérrez Bautista ÁJ, Viscasillas J, Redondo JI. Agreement of a veterinary-specific oscillometric noninvasive arterial blood pressure monitor (SunTech Vet30) with invasive arterial blood pressure in anaesthetised horses. Veterinary Anaesthesia and Analgesia. 2026. doi:10.1016/j.vaa.2026.101284
BibTeX
@article{HernndezMagaa2026,
author = {Hernández-Magaña, Eva Zoe and Gutiérrez Bautista, Álvaro-Jesús and Viscasillas, Jaime and Redondo, José I},
title = {Agreement of a veterinary-specific oscillometric noninvasive arterial blood pressure monitor (SunTech Vet30) with invasive arterial blood pressure in anaesthetised horses},
journal = {Veterinary Anaesthesia and Analgesia},
year = {2026},
doi = {10.1016/j.vaa.2026.101284}
}
EUVIMED