EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Accuracy and trending ability of a pulse contour cardiac output monitor (LiDCO™ plus) calibrated with echocardiography in anesthetized dogs: a preliminary study

Dongseok Kim, Yujung Shin, Inseo Lee, Sang-Kwon Lee, Yoonhoi Koo, Won-Jae Lee, Sung-Ho Yun, Young-Sam Kwon, Min Jang

Veterinary Anaesthesia and Analgesia · 2026

DOI: 10.1016/j.vaa.2026.101197 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary Anaesthesia and Analgesia, 2026. Verfasst von Dongseok Kim und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Kyungpook National University, Daegu, Republic of Korea. Electronic addre…. Hauptthemen laut MEDLINE: Anesthesia, General, Cardiac Output, Echocardiography, Monitoring, Intraoperative. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Research Foundation of Korea, Korea Ministry of Science and ICT.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: To evaluate the accuracy, agreement, and trending ability of the pulse contour cardiac output (PulseCO) system calibrated with echocardiography-derived cardiac output (CO) in sevoflurane-anesthetized healthy dogs during 8 hours of general anesthetic. STUDY DESIGN: Prospective, randomized, blinded experimental study. ANIMALS: A total of five healthy Beagle dogs, three intact females and two intact males. METHODS: Dogs were anesthetized using intravenous alfaxalone for induction and sevoflurane in 100% oxygen for maintenance for 8 hours. CO was estimated using three methods: pulmonary artery catheter thermodilution (PAC-TD)-derived CO (COPAC-TD), Doppler-based echocardiography-derived CO (COEcho), and PulseCO-derived CO (COPulseCO). The PulseCO monitor was calibrated at baseline using COEcho and not recalibrated during the anesthetic. Measurements were taken at baseline and at intervals up to 8 hours. All CO values were converted to cardiac index (CI) by indexing to body surface area. Statistical analysis included Bland-Altman and linear regression analyses for agreement assessment and Critchley's four-quadrant and polar plots for trending analysis. RESULTS: A total of 100 paired CI measurements were obtained. Bland-Altman analysis revealed a mean bias of -0.1 L minute-1 m-2 and percentage error of 28.3% for CIPAC-TDversus CIPulseCO, and a mean bias of 0.01 L minute-1 m-2 with a percentage error of 24.9% for CIPAC-TDversus CIEcho. Trending analysis between CIPAC-TD and CIPulseCO showed a concordance rate of 98.2% in the four-quadrant plot and a mean angular bias of 2.6 ° with radial limits of agreement ranging from -21.47 ° to 26.67 ° in the polar plot. CONCLUSIONS AND CLINICAL RELEVANCE: The results indicate that the PulseCO system has acceptable accuracy, agreement, and trending ability compared with the traditional reference method of PAC-TD. This highlights the potential of the PulseCO system as a minimally invasive and practical monitoring tool in sevoflurane-anesthetized dogs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Anesthesia, GeneralCardiac OutputEchocardiographyMonitoring, IntraoperativeAnimalsDogsFemaleMaleAnesthetics, InhalationCalibrationMethyl EthersProspective StudiesSevoflurane

Stichwörter der Autor:innen

PulseCOcardiac outputdogechocardiographythermodilution

Substanzen

Anesthetics, InhalationMethyl EthersSevoflurane

Autor:innen und Institutionen

  • Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Kyungpook National University, Daegu, Republic of Korea. Electronic address: tjrjej@gmail.com.
  • Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Kyungpook National University, Daegu, Republic of Korea.
  • Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Kyungpook National University, Daegu, Republic of Korea. Electronic address: jangmin@knu.ac.kr.

Förderung

  • National Research Foundation of Korea
  • Korea Ministry of Science and ICT

Zitieren

APA

Kim, D., Shin, Y., Lee, I., Lee, S. K., Koo, Y., Lee, W. J., Yun, S. H., Kwon, Y. S., & Jang, M. (2026). Accuracy and trending ability of a pulse contour cardiac output monitor (LiDCO™ plus) calibrated with echocardiography in anesthetized dogs: a preliminary study. Veterinary Anaesthesia and Analgesia. https://doi.org/10.1016/j.vaa.2026.101197

Vancouver

Kim D, Shin Y, Lee I, Lee SK, Koo Y, Lee WJ, et al. Accuracy and trending ability of a pulse contour cardiac output monitor (LiDCO™ plus) calibrated with echocardiography in anesthetized dogs: a preliminary study. Veterinary Anaesthesia and Analgesia. 2026. doi:10.1016/j.vaa.2026.101197

BibTeX
@article{Kim2026,
  author = {Kim, Dongseok and Shin, Yujung and Lee, Inseo and Lee, Sang-Kwon and Koo, Yoonhoi and Lee, Won-Jae and Yun, Sung-Ho and Kwon, Young-Sam and Jang, Min},
  title = {Accuracy and trending ability of a pulse contour cardiac output monitor (LiDCO™ plus) calibrated with echocardiography in anesthetized dogs: a preliminary study},
  journal = {Veterinary Anaesthesia and Analgesia},
  year = {2026},
  doi = {10.1016/j.vaa.2026.101197}
}
Kostenlos starten →