Evaluation of lingual oscillometric blood pressure measurement in anaesthetized pigs
Veterinary Anaesthesia and Analgesia · 2024
DOI: 10.1016/j.vaa.2024.06.013 ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift Veterinary Anaesthesia and Analgesia, 2024. Verfasst von Charles Makepeace und 2 weiteren Autor:innen. Beteiligte Einrichtung: Langford Vets and Translational Biomedical Research Centre, University of Bristol, Langford, Bristol, UK. Electronic address: cm9313@my.bristol.ac.uk. Hauptthemen laut MEDLINE: Blood Pressure Determination, Oscillometry, Tongue, Blood Pressure. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
OBJECTIVE: To evaluate the agreement between measurements of invasive blood pressure (IBP) and oscillometric blood pressure from the tongue (OBPton) using a multiparameter monitor. STUDY DESIGN: Unblinded, prospective, experimental study. ANIMALS: A total of 12 female Large White crossbreed pigs. METHODS: Pigs undergoing experimental procedures that required arterial cannula placement were recruited. A blood pressure cuff with the closest width to 40% of the circumference of the tongue was placed rostral to the lingual frenulum. Systolic, mean and diastolic IBP and OBPton were measured simultaneously at 5 minute intervals. Agreement between paired measurements was examined using Bland-Altman analysis. Mean bias, precision (standard deviation of mean bias), 95% limits of agreement, correlation coefficients and percentage of measurements within 10 and 20 mmHg of IBP were calculated. RESULTS: The total numbers of paired measurements recorded were 124, 126 and 124 for systolic, mean and diastolic blood pressures, respectively. The mean bias, precision and 95% limits of agreement for systolic OBPton were 11.5, 11.5 (-11.1 to 34.2), for mean OBPton 5.6, 5.7 (-5.7 to 16.8) and for diastolic OBPton 7.6, 10.1 (-12.1 to 27.4) mmHg. Correlation coefficients were greater than 0.9 for mean OBPton only. More than 50% of measurements were within 10 mmHg of IBP and 80% of measurements were within 20 mmHg of IBP for mean and diastolic OBPton only. CONCLUSIONS AND CLINICAL RELEVANCE: The tongue as a cuff site for oscillometric blood pressure measurement is a useful site for measuring mean arterial, but not systolic or diastolic blood pressure in anaesthetized Large White crossbreed pigs. This technique fulfils the American College of Veterinary Internal Medicine criteria for measuring mean arterial pressure but not systolic or diastolic arterial pressure.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Langford Vets and Translational Biomedical Research Centre, University of Bristol, Langford, Bristol, UK. Electronic address: cm9313@my.bristol.ac.uk.
- Langford Vets and Translational Biomedical Research Centre, University of Bristol, Langford, Bristol, UK.
Zitieren
APA
Makepeace, C., Macfarlane, P., & Deutsch, J. (2024). Evaluation of lingual oscillometric blood pressure measurement in anaesthetized pigs. Veterinary Anaesthesia and Analgesia. https://doi.org/10.1016/j.vaa.2024.06.013
Vancouver
Makepeace C, Macfarlane P, Deutsch J. Evaluation of lingual oscillometric blood pressure measurement in anaesthetized pigs. Veterinary Anaesthesia and Analgesia. 2024. doi:10.1016/j.vaa.2024.06.013
BibTeX
@article{Makepeace2024,
author = {Makepeace, Charles and Macfarlane, Paul and Deutsch, Julia},
title = {Evaluation of lingual oscillometric blood pressure measurement in anaesthetized pigs},
journal = {Veterinary Anaesthesia and Analgesia},
year = {2024},
doi = {10.1016/j.vaa.2024.06.013}
}