Clinical and Operational Evaluation of Hypothermic Machine Perfusion for Kidney Transplantation in a Brazilian Reference Center
Transplantation Proceedings · 2026
DOI: 10.1016/j.transproceed.2026.06.030 ↗Kurz gefasst
Fachartikel in der Zeitschrift Transplantation Proceedings, 2026. Verfasst von Petrúcia Maria Antero Pinheiro und 5 weiteren Autor:innen. Beteiligte Einrichtung: Renal Transplant Unit, Hospital Geral de Fortaleza-HGF, Fortaleza, Brazil; Postgraduate Program in Public Health, Universidade de Fortaleza-UNIFOR, F…. Hauptthemen laut MEDLINE: Kidney Transplantation, Perfusion, Hypothermia, Induced, Organ Preservation. Die Arbeit nennt 13 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Hypothermic machine perfusion (MP) improves outcomes in kidney transplantation, but evidence from low- and middle-income countries (LMICs) and public health settings is limited. This study evaluated clinical and operational performances of MP in the first and largest Brazilian renal perfusion service. METHODS: This single-center study was conducted at a Brazilian public hospital. Operational performance was evaluated through a qualitative observational analysis using a 20-item questionnaire applied to 7 transplant surgeons and perfusion nurses, based on national medical device assessment guidelines. Clinical outcomes were assessed in a longitudinal cohort of 212 deceased-donor kidney transplant recipients. Kidneys preserved with MP after an initial period of static cold storage (MP group, n = 100) were compared with those preserved exclusively with static cold storage (SCS group, n = 112). Outcomes included delayed graft function (DGF), dialysis requirement, length of hospital stay, and one-year graft and patient survival. Final data collection and analysis were completed in September 2025. RESULTS: Operational evaluation was preponderantly favorable, supporting the sustainable use of MP, which was associated with a lower incidence of DGF compared with SCS (25% vs 46.5%; p = .002) and independently associated with lower odds of DGF (OR = 0,38; CI 95%: 0,21-0,69). MP recipients required fewer dialysis sessions and had shorter hospital stays. Graft function, rejection rates, and one-year graft and patient survival were similar between groups. CONCLUSIONS: In a real-life LMIC public health setting, MP was operationally sustainable and reduced DGF after kidney transplantation, supporting its use in resource-constrained transplant programs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Renal Transplant Unit, Hospital Geral de Fortaleza-HGF, Fortaleza, Brazil; Postgraduate Program in Public Health, Universidade de Fortaleza-UNIFOR, Fortaleza, Brazil; Medical Evaluation Department, Instituto Federal de…
- Postgraduate Program in Public Health, Universidade de Fortaleza-UNIFOR, Fortaleza, Brazil; Medical Evaluation Department, Instituto Federal de Educação, Ciência e Tecnologia do Ceará-IFCE, Fortaleza, Brazil.
- Renal Transplant Unit, Hospital Geral de Fortaleza-HGF, Fortaleza, Brazil.
Zitieren
APA
Pinheiro, P. M. A., Junior, G. B. D. S., Sandes-Freitas, T. V., Freire, J. M. M., Andrade, M. B. A., & Esmeraldo, R. M. (2026). Clinical and Operational Evaluation of Hypothermic Machine Perfusion for Kidney Transplantation in a Brazilian Reference Center. Transplantation Proceedings. https://doi.org/10.1016/j.transproceed.2026.06.030
Vancouver
Pinheiro PMA, Junior GBDS, Sandes-Freitas TV, Freire JMM, Andrade MBA, Esmeraldo RM. Clinical and Operational Evaluation of Hypothermic Machine Perfusion for Kidney Transplantation in a Brazilian Reference Center. Transplantation Proceedings. 2026. doi:10.1016/j.transproceed.2026.06.030
BibTeX
@article{Pinheiro2026,
author = {Pinheiro, Petrúcia Maria Antero and Junior, Geraldo Bezerra da Silva and Sandes-Freitas, Tainá Veras and Freire, Janaína Maria Maia and Andrade, Marilha Braga Alves and Esmeraldo, Ronaldo de Matos},
title = {Clinical and Operational Evaluation of Hypothermic Machine Perfusion for Kidney Transplantation in a Brazilian Reference Center},
journal = {Transplantation Proceedings},
year = {2026},
doi = {10.1016/j.transproceed.2026.06.030}
}
EUVIMED