EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

A deep learning image analysis method for renal perfusion estimation in pseudo-continuous arterial spin labelling MRI

Anne Oyarzun-Domeño, Izaskun Cia, Rebeca Echeverria-Chasco, María A Fernández-Seara, Paloma L Martin-Moreno, Nuria Garcia-Fernandez, Gorka Bastarrika, Javier Navallas, Arantxa Villanueva

Magnetic Resonance Imaging · 2023

DOI: 10.1016/j.mri.2023.09.007 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2023. Verfasst von Anne Oyarzun-Domeño und 8 weiteren Autor:innen. Beteiligte Einrichtung: Electrical Electronics and Communications Engineering, Public University of Navarre, 31006 Pamplona, Spain; IdiSNA, Health Research Institute of Nava…. Hauptthemen laut MEDLINE: Spin Labels, Deep Learning, Kidney Transplantation, Kidney. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate segmentation of renal tissues is an essential step for renal perfusion estimation and postoperative assessment of the allograft. Images are usually manually labeled, which is tedious and prone to human error. We present an image analysis method for the automatic estimation of renal perfusion based on perfusion magnetic resonance imaging. Specifically, non-contrasted pseudo-continuous arterial spin labeling (PCASL) images are used for kidney transplant evaluation and perfusion estimation, as a biomarker of the status of the allograft. The proposed method uses machine/deep learning tools for the segmentation and classification of renal cortical and medullary tissues and automates the estimation of perfusion values. Data from 16 transplant patients has been used for the experiments. The automatic analysis of differentiated tissues within the kidney, such as cortex and medulla, is performed by employing the time-intensity-curves of non-contrasted T1-weighted MRI series. Specifically, using the Dice similarity coefficient as a figure of merit, results above 93%, 92% and 82% are obtained for whole kidney, cortex, and medulla, respectively. Besides, estimated cortical and medullary perfusion values are considered to be within the acceptable ranges within clinical practice.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Spin LabelsDeep LearningKidney TransplantationKidneyImage Processing, Computer-AssistedMagnetic Resonance ImagingHumansFemaleMaleAdultMiddle AgedRenal CirculationPerfusion

Stichwörter der Autor:innen

AllograftDeep learningMRIRenal perfusionSegmentation

Substanzen

Spin Labels

Autor:innen und Institutionen

  • Electrical Electronics and Communications Engineering, Public University of Navarre, 31006 Pamplona, Spain; IdiSNA, Health Research Institute of Navarra, 31008, Spain. Electronic address: anne.oyarzun@unavarra.es.
  • Electrical Electronics and Communications Engineering, Public University of Navarre, 31006 Pamplona, Spain. Electronic address: izaskun.cia@unavarra.es.
  • IdiSNA, Health Research Institute of Navarra, 31008, Spain; Department of Radiology, Clínica Universidad de Navarra, 31008 Pamplona, Spain. Electronic address: recheverriac@unav.es.
  • IdiSNA, Health Research Institute of Navarra, 31008, Spain; Department of Radiology, Clínica Universidad de Navarra, 31008 Pamplona, Spain. Electronic address: mfseara@unav.es.
  • IdiSNA, Health Research Institute of Navarra, 31008, Spain; Department of Nephrology, Clínica Universidad de Navarra, 31008 Pamplona, Spain. Electronic address: plmartin@unav.es.
  • IdiSNA, Health Research Institute of Navarra, 31008, Spain; Department of Nephrology, Clínica Universidad de Navarra, 31008 Pamplona, Spain. Electronic address: nrgarcia@unav.es.

Zitieren

APA

Oyarzun-Domeño, A., Cia, I., Echeverria-Chasco, R., Fernández-Seara, M. A., Martin-Moreno, P. L., Garcia-Fernandez, N., Bastarrika, G., Navallas, J., & Villanueva, A. (2023). A deep learning image analysis method for renal perfusion estimation in pseudo-continuous arterial spin labelling MRI. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2023.09.007

Vancouver

Oyarzun-Domeño A, Cia I, Echeverria-Chasco R, Fernández-Seara MA, Martin-Moreno PL, Garcia-Fernandez N, et al. A deep learning image analysis method for renal perfusion estimation in pseudo-continuous arterial spin labelling MRI. Magnetic Resonance Imaging. 2023. doi:10.1016/j.mri.2023.09.007

BibTeX
@article{OyarzunDomeo2023,
  author = {Oyarzun-Domeño, Anne and Cia, Izaskun and Echeverria-Chasco, Rebeca and Fernández-Seara, María A and Martin-Moreno, Paloma L and Garcia-Fernandez, Nuria and Bastarrika, Gorka and Navallas, Javier and Villanueva, Arantxa},
  title = {A deep learning image analysis method for renal perfusion estimation in pseudo-continuous arterial spin labelling MRI},
  journal = {Magnetic Resonance Imaging},
  year = {2023},
  doi = {10.1016/j.mri.2023.09.007}
}
Kostenlos starten →