Simultaneous quantification of fourteen urinary tobacco biomarkers via UHPLC-Q-Orbitrap HRMS and isotope dilution
Talanta · 2026
DOI: 10.1016/j.talanta.2026.129448 ↗Kurz gefasst
Fachartikel in der Zeitschrift Talanta, 2026. Verfasst von Changming Ding und 5 weiteren Autor:innen. Beteiligte Einrichtung: China CDC Key Laboratory of Environment and Population Health, National Institute of Environmental Health, Chinese Center for Disease Control and Pre…. Hauptthemen laut MEDLINE: Biomarkers, Nicotine, Smoking. Die Arbeit nennt 43 Literaturangaben. Gefördert von: National Major Science and Technology Projects of China, Key Technologies Research and Development Program, National Natural Science Foundation of China.
Abstract (Originalsprache)
This study developed and validated an ultra-high-performance liquid chromatography-quadrupole-Orbitrap high-resolution mass spectrometry(UHPLC-Q-Orbitrap HRMS)method for the simultaneous quantitative 14 tobacco biomarkers in human urine. This method encompasses biomarkers including nicotine metabolites, tobacco-specific nitrosamine metabolites, and minor tobacco alkaloids. Sample preparation employed a combination of enzymatic digestion and supported liquid extraction (SLE), coupled with isotopically labeled internal standards. Analyte separation was achieved rapidly using a Gemini NX-C18 column (150 mm × 2.0 mm, 3 μm), enabling detection of all target compounds within a 15-min chromatographic run time. High-resolution mass spectrometry (HRMS) operated in Full MS and parallel reaction monitoring (PRM) modes. Precise mass screening of parent ions was performed, with confirmation achieved through isotope-labeled internal standards and secondary fragment information. This method has undergone comprehensive validation, demonstrating excellent linearity for all analytes within their respective dynamic ranges. Accuracy ranged from 82.9 % to 121 %, with within-day precision between 1.0 % and 13 % and between-day precision between 1.7 % and 25 %. The limit of detection (LOD) ranged from 0.003 to 2 μg/L, while the limit of quantification (LOQ) spanned 0.01-5 μg/L. Furthermore, matrix effects, recovery rates, and stability all complied with the requirements of bioanalytical guidelines. Ultimately, this method was applied to 123 urine samples from the China National Human Biomarker Monitoring Program (CNHBM), including 30 smokers and 93 non-smokers. The results revealed significant differences in biomarker levels between groups with varying smoking statuses, demonstrating the method's potential for application in epidemiological studies and evaluation of tobacco exposure.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- China CDC Key Laboratory of Environment and Population Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing, 100021, China; National Key Laboratory of Intelligen…
- China CDC Key Laboratory of Environment and Population Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing, 100021, China; School of Public Health, Anhui Medica…
- China CDC Key Laboratory of Environment and Population Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing, 100021, China.
Förderung
- National Major Science and Technology Projects of China
- Key Technologies Research and Development Program
- National Natural Science Foundation of China
- National Science and Technology Major Project
- National Key Research and Development Program of China
Zitieren
APA
Ding, C., Yang, Y., Yin, J., Liu, G., Lu, Y., & Shi, X. (2026). Simultaneous quantification of fourteen urinary tobacco biomarkers via UHPLC-Q-Orbitrap HRMS and isotope dilution. Talanta. https://doi.org/10.1016/j.talanta.2026.129448
Vancouver
Ding C, Yang Y, Yin J, Liu G, Lu Y, Shi X. Simultaneous quantification of fourteen urinary tobacco biomarkers via UHPLC-Q-Orbitrap HRMS and isotope dilution. Talanta. 2026. doi:10.1016/j.talanta.2026.129448
BibTeX
@article{Ding2026,
author = {Ding, Changming and Yang, Yongjie and Yin, Jin and Liu, Guannian and Lu, Yifu and Shi, Xiaoming},
title = {Simultaneous quantification of fourteen urinary tobacco biomarkers via UHPLC-Q-Orbitrap HRMS and isotope dilution},
journal = {Talanta},
year = {2026},
doi = {10.1016/j.talanta.2026.129448}
}
EUVIMED