EUVIMEDEUVIMED entdecken
Evaluationsstudie

Evaluation of portable atmospheric-pressure solids analysis probe–quadrupole mass spectrometry and UPLC−MS for the rapid screening of illicit substances in human urine

Doreen N B Chandra Siri, Si Ling Ng, Ngee Sing Chong, Philip J Marriott, Yong Foo Wong

Journal of Chromatography A · 2026

DOI: 10.1016/j.chroma.2026.466720 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Journal of Chromatography A, 2026. Verfasst von Doreen N B Chandra Siri und 4 weiteren Autor:innen. Beteiligte Einrichtung: Center for Research on Multidimensional Separation Science, School of Chemical Sciences, Universiti Sains Malaysia, 11800 Penang, Malaysia; Toxicolog…. Hauptthemen laut MEDLINE: Illicit Drugs, Liquid Chromatography-Mass Spectrometry, Mass Spectrometry, Substance Abuse Detection. Die Arbeit nennt 82 Literaturangaben. Gefördert von: Waters Corporation, Science University of Malaysia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Atmospheric-pressure solids analysis probe (ASAP) is an ambient pressure ionisation mass spectrometry technique that allows the direct analysis of liquids and solids, with or without sample preparation, producing rapid, efficient, and real-time results. In this study, portable ASAP-quadrupole mass spectrometry (ASAP-QMS) method in positive ion mode was demonstrated for the rapid analysis of 9 drugs of abuse (amphetamine, methamphetamine, oxycodone, methadone, morphine, 3,4-methylenedioxymethamphetamine, ketamine, 6-monoacetylmorphine, and cocaine), fortified in water and urine samples, with analysis time of ∼30 s. Initially, a direct analysis approach without sample preparation was applied to fortified water and urine samples. However, significant urine matrix effects were observed, leading to ion suppression and detector saturation. A simple solid-phase extraction (SPE) procedure was then applied to reduce matrix effects arising from the urine samples. The influence of cone voltages on the fragmentation and abundance of molecular ions for the illicit compounds was evaluated. The analytes exhibited limits of detection in the range of 0.3 - 2 µg mL-1, which were considerably higher than the UPLC-ESIMS (0.05 - 0.1 µg mL-1) method. Drug compounds identification was performed via MS spectrum matching against an in-house database. Comparative assessment with UPLC-ESI linear ion trap MS using United Nations Office on Drugs and Crime International Collaborative Exercises urine samples showed detection accuracies of 43% for ASAP-QMS and 100% for the UPLC-MS method. The lower accuracy of ASAP-QMS was attributed to the poor spectral library matching (similarity scores < 850) in complex urine matrices, particularly for low-concentration drug compounds. Nevertheless, portable ASAP-QMS (with SPE) achieved a higher greenness assessment score (0.54) compared to UPLC-MS (0.37), highlighting its potential as a rapid and environmentally friendly drug screening approach.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Illicit DrugsLiquid Chromatography-Mass SpectrometryMass SpectrometrySubstance Abuse DetectionHumansSolid Phase ExtractionLimit of DetectionChromatography, High Pressure LiquidReproducibility of ResultsAtmospheric Pressure

Stichwörter der Autor:innen

Ambient-pressure ionisation mass spectrometryAtmospheric-pressure solids analysis probeCocaineIllicit drugsUrine

Substanzen

Illicit Drugs

Autor:innen und Institutionen

  • Center for Research on Multidimensional Separation Science, School of Chemical Sciences, Universiti Sains Malaysia, 11800 Penang, Malaysia; Toxicology Section, Forensic Division, Department of Chemistry Malaysia Penang…
  • School of Chemical Sciences, Universiti Sains Malaysia, 11800 Penang, Malaysia.
  • Department of Chemistry, Middle Tennessee State University, Murfreesboro, TN 37132, United States.
  • Australian Centre for Research on Separation Science, School of Chemistry, Monash University, Wellington Road, Clayton, Victoria 3800, Australia.
  • Center for Research on Multidimensional Separation Science, School of Chemical Sciences, Universiti Sains Malaysia, 11800 Penang, Malaysia. Electronic address: wongyongfoo@usm.my.

Förderung

  • Waters Corporation
  • Science University of Malaysia

Zitieren

APA

Siri, D. N. B. C., Ng, S. L., Chong, N. S., Marriott, P. J., & Wong, Y. F. (2026). Evaluation of portable atmospheric-pressure solids analysis probe–quadrupole mass spectrometry and UPLC−MS for the rapid screening of illicit substances in human urine. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2026.466720

Vancouver

Siri DNBC, Ng SL, Chong NS, Marriott PJ, Wong YF. Evaluation of portable atmospheric-pressure solids analysis probe–quadrupole mass spectrometry and UPLC−MS for the rapid screening of illicit substances in human urine. Journal of Chromatography A. 2026. doi:10.1016/j.chroma.2026.466720

BibTeX
@article{Siri2026,
  author = {Siri, Doreen N B Chandra and Ng, Si Ling and Chong, Ngee Sing and Marriott, Philip J and Wong, Yong Foo},
  title = {Evaluation of portable atmospheric-pressure solids analysis probe–quadrupole mass spectrometry and UPLC−MS for the rapid screening of illicit substances in human urine},
  journal = {Journal of Chromatography A},
  year = {2026},
  doi = {10.1016/j.chroma.2026.466720}
}
Kostenlos starten →