Sweet-responsive magnetic metal-organic framework for point-of-care testing of ATP using personal glucose meter
Talanta · 2026
DOI: 10.1016/j.talanta.2025.129337 ↗Kurz gefasst
Fachartikel in der Zeitschrift Talanta, 2026. Verfasst von Fujing Jin und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Biomedical Precision Testing and Instrumentation, College of Artificial Intelligence, Taiyuan University of Technology, Taiyuan, Shanxi,…. Hauptthemen laut MEDLINE: Adenosine Triphosphate, Metal-Organic Frameworks, Point-of-Care Testing, Magnetite Nanoparticles. Die Arbeit nennt 56 Literaturangaben. Gefördert von: Shanxi Province Natural Science Foundation, Fujian Provincial Natural Science Foundation, Taiyuan University of Technology.
Abstract (Originalsprache)
Personal glucose meter (PGM) is recognized as one of the most commercially available point-of-care testing (POCT) device for routine glucose monitoring. However, PGM-based analysis of non-glucose target is limited because of the complicated modification of glucose-related enzyme. Herein, we proposed a POCT sensing platform based on sweet-responsive magnetic MOF probe and PGM for the quantitative detection of non-glucose target. Glucose oxidase (GOx) and magnetic nanoparticles (MNPs) were co-encapsulated into the amorphous zeolitic imidazole framework-90 (aZIF-90) to form the probe and adenosine triphosphate (ATP) was chosen as the model target. The sensing probe couples the excellent affinity of aZIF-90 to ATP with the magnetic-responsive capability of MNPs, enabling the effective release and separation of free GOx. Under the assistance of PGM, the ATP level can be quantitatively determined by the GOx-based glucose consumption. A pretty wide detection range of 0.5-1000 μM and a low limit of detection of 81.01 nM were obtained. The sensing platform also displayed excellent detection performance in complicated real sample with recovery rates ranging from 93.98 % to 107.85 %. Therefore, this study provides an equipment-free and portable sensing platform for POCT sensing and sheds new light on repurposing PGM for non-glucose target analysis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Institute of Biomedical Precision Testing and Instrumentation, College of Artificial Intelligence, Taiyuan University of Technology, Taiyuan, Shanxi, 030024, China.
- College of Materials and Chemical Engineering, Minjiang University, Fuzhou, Fujian, 350108, China.
- Institute of Biomedical Precision Testing and Instrumentation, College of Artificial Intelligence, Taiyuan University of Technology, Taiyuan, Shanxi, 030024, China. Electronic address: wangyingqian@tyut.edu.cn.
Förderung
- Shanxi Province Natural Science Foundation
- Fujian Provincial Natural Science Foundation
- Taiyuan University of Technology
- National Natural Science Foundation of China
Zitieren
APA
Jin, F., Wen, Z., Ding, D., Liang, L., Ren, J., & Wang, Y. (2026). Sweet-responsive magnetic metal-organic framework for point-of-care testing of ATP using personal glucose meter. Talanta. https://doi.org/10.1016/j.talanta.2025.129337
Vancouver
Jin F, Wen Z, Ding D, Liang L, Ren J, Wang Y. Sweet-responsive magnetic metal-organic framework for point-of-care testing of ATP using personal glucose meter. Talanta. 2026. doi:10.1016/j.talanta.2025.129337
BibTeX
@article{Jin2026,
author = {Jin, Fujing and Wen, Zhihan and Ding, Dianxing and Liang, Ling and Ren, Jiamin and Wang, Yingqian},
title = {Sweet-responsive magnetic metal-organic framework for point-of-care testing of ATP using personal glucose meter},
journal = {Talanta},
year = {2026},
doi = {10.1016/j.talanta.2025.129337}
}
EUVIMED