EUVIMEDEUVIMED entdecken
Crossref

Development of a ZIF-8/LIG-based electrochemical biosensor for accurate and reliable glucose monitoring in blood

Xia Kuang, Guocai Zhao, Jingyi Guo, Qin Tang, Jun Yu, Fang Wang

Microchimica Acta · 2025-07 · 192 (7)

DOI: 10.1007/s00604-025-07302-x ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microchimica Acta, online erschienen am 19.06.2025. Verfasst von Xia Kuang und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Pharmaceutical Sciences, Key Laboratory of Combinatorial Biosynthesis and Drug Discovery (MOE), Wuhan University, Wuhan, 430071, China. Hauptthemen laut MEDLINE: Biosensing Techniques, Blood Glucose, Metal-Organic Frameworks, Electrochemical Techniques. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: National Natural Science Foundation of China, the Noncommunicable Chronic Diseases-National Science and Technology Major Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Harnessing the exceptional enzyme immobilization capabilities of metal-organic frameworks (MOFs) and the exceptional electrochemical characteristics of graphene, we designed a highly efficient and cost-effective glucose sensor utilizing zeolitic imidazolate framework-8 (ZIF-8) and laser-induced graphene (LIG) with the aid of mediator ferrocene (Fc). By incorporating a cellulose acetate (CA) film as an anti-interference layer and a polyurethane (PU) film as a diffusion-limiting layer, the sensor exhibited a wide linear detection range for glucose (0.62 mM to 20 mM) with a low detection limit of 0.16 mM (S/N = 3). Notably, it demonstrated excellent selectivity, with no interference from common biological substances. The sensor also exhibited good stability, retaining 96.38% of its initial performance after 7 days of storage. Additionally, the sensor was effectively utilized for glucose detection in whole blood, with results closely matching those obtained from a commercial blood gas analyzer (GEM5000), as evidenced by a high Pearson's correlation coefficient (r = 0.9974). This method provides a portable glucose sensor that produces results highly consistent with those obtained from large-scale testing devices in hospitals, enabling convenient and accurate blood glucose monitoring for patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesBlood GlucoseMetal-Organic FrameworksElectrochemical TechniquesGraphiteZeolitesHumansLimit of DetectionGlucose OxidaseMetallocenesFerrous CompoundsEnzymes, ImmobilizedImidazoles

Stichwörter der Autor:innen

Cyclic voltammetryElectrochemical biosensorGlucoseLaser-induced grapheneMetal organic frameworksZeolitic imidazolate frameworks

Substanzen

Blood GlucoseMetal-Organic FrameworksGraphiteGlucose OxidaseMetallocenesZeolitesFerrous CompoundsEnzymes, ImmobilizedferroceneZIF-8 metal-organic framework

Autor:innen und Institutionen

  • School of Pharmaceutical Sciences, Key Laboratory of Combinatorial Biosynthesis and Drug Discovery (MOE), Wuhan University, Wuhan, 430071, China.
  • Wuhan EasyDiagnosis Biomedicine Co., Ltd, Wuhan, China.
  • School of Pharmaceutical Sciences, Key Laboratory of Combinatorial Biosynthesis and Drug Discovery (MOE), Wuhan University, Wuhan, 430071, China. fwang@whu.edu.cn.

Förderung

  • National Natural Science Foundation of China
  • the Noncommunicable Chronic Diseases-National Science and Technology Major Project

Zitieren

APA

Kuang, X., Zhao, G., Guo, J., Tang, Q., Yu, J., & Wang, F. (2025). Development of a ZIF-8/LIG-based electrochemical biosensor for accurate and reliable glucose monitoring in blood. Microchimica Acta, 192(7). https://doi.org/10.1007/s00604-025-07302-x

Vancouver

Kuang X, Zhao G, Guo J, Tang Q, Yu J, Wang F. Development of a ZIF-8/LIG-based electrochemical biosensor for accurate and reliable glucose monitoring in blood. Microchimica Acta. 2025;192(7). doi:10.1007/s00604-025-07302-x

BibTeX
@article{Kuang2025,
  author = {Kuang, Xia and Zhao, Guocai and Guo, Jingyi and Tang, Qin and Yu, Jun and Wang, Fang},
  title = {Development of a ZIF-8/LIG-based electrochemical biosensor for accurate and reliable glucose monitoring in blood},
  journal = {Microchimica Acta},
  year = {2025},
  volume = {192},
  number = {7},
  doi = {10.1007/s00604-025-07302-x}
}
Kostenlos starten →