EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Monitoring of indoor air quality at a large sailing cruise ship to assess ventilation performance and disease transmission risk

Ho Yin Wickson Cheung, Prashant Kumar, Sarkawt Hama, Ana Paula Mendes Emygdio, Yingyue Wei, Lemonia Anagnostopoulos, John Ewer, Valerio Ferracci, Edwin R Galea, Angus Grandison, Christos Hadjichristodoulou, Fuchen Jia und 6 weitere

Science of The Total Environment · 2025

DOI: 10.1016/j.scitotenv.2024.178286 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Science of The Total Environment, 2025. Verfasst von Ho Yin Wickson Cheung und 17 weiteren Autor:innen. Beteiligte Einrichtung: Global Centre for Clean Air Research (GCARE), Department of Civil and Environmental Engineering, Faculty of Engineering and Physical Sciences, Univer…. Hauptthemen laut MEDLINE: Air Pollution, Indoor, Ventilation, Ships, Environmental Monitoring. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 104 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Horizon Europe.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Large passenger ships are characterised as enclosed and crowded indoor spaces with frequent interactions between travellers, providing conditions that facilitate disease transmission. This study aims to provide an indoor ship CO2 dataset for inferring thermal comfort, ventilation and infectious disease transmission risk evaluation. Indoor air quality (IAQ) monitoring was conducted in nine environments (three cabins, buffet, gym, bar, restaurant, pub and theatre), on board a cruise ship voyaging across the UK and EU, with the study conducted in the framework of the EU HEALTHY SAILING project. CO2 concentrations, temperature and relative humidity (RH) were simultaneously monitored to investigate thermal characteristics and effectiveness of ventilation performance. Results show a slightly higher RH of 68.2 ± 5.3 % aboard compared to ASHRAE and ISO recommended targets, with temperature recorded at 22.3 ± 1.4 °C. Generally, good IAQ ( 20 L s-1 person-1) were highly over-ventilated. Dining areas including the pub and restaurant recorded high CO2 concentrations (>2000 ppm) potentially due to higher footfall (0.6 person m-2 and 0.4 person m-2) and limited ACH (2.3 h-1 and 0.8 h-1), indicating a potential risk of infection; these areas should be prioritised for improvement. The IAQ and probability of infection indicate there is an opportunity for energy saving by lowering hotel load for the theatre and cabins and achieving the minimum acceptable VR (10 L s-1 person-1) for occupants' comfort and disease control. Our study produced a first-time dataset from a sailing cruise ship's ventilated areas and provided evidence that can inform guidelines about the optimisation of ventilation operations in large passenger ships, contributing to respiratory health, infection control and energy efficiency aboard.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Air Pollution, IndoorVentilationShipsEnvironmental MonitoringHumansCarbon DioxideRisk AssessmentCommunicable Diseases

Stichwörter der Autor:innen

CO(2)Cruise shipIndoor air qualityInfectious transmission riskThermal comfortVentilation

Substanzen

Carbon Dioxide

Autor:innen und Institutionen

  • Global Centre for Clean Air Research (GCARE), Department of Civil and Environmental Engineering, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford GU2 7XH, United Kingdom.
  • Global Centre for Clean Air Research (GCARE), Department of Civil and Environmental Engineering, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford GU2 7XH, United Kingdom; Institute for Susta…
  • Global Centre for Clean Air Research (GCARE), Department of Civil and Environmental Engineering, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford GU2 7XH, United Kingdom; Atmospheric Environ…
  • Laboratory of Hygiene and Epidemiology, Faculty of Medicine, University of Thessaly, Larissa 41222, Greece.
  • Centre for Safety, Resilience and Protective Security, Fire Safety Engineering Group, School of Computing and Mathematical Sciences, Faculty of Engineering and Science, University of Greenwich, Greenwich SE10 9LS, Unite…
  • Atmospheric Environmental Science Department, National Physical Laboratory (NPL), Hampton Road, Teddington, Middlesex TW11 0LW, United Kingdom.

Förderung

  • Horizon Europe

Zitieren

APA

Cheung, H. Y. W., Kumar, P., Hama, S., Emygdio, A. P. M., Wei, Y., Anagnostopoulos, L., Ewer, J., Ferracci, V., Galea, E. R., Grandison, A., Hadjichristodoulou, C., Jia, F., Lepore, P., Morawska, L., Mouchtouri, V. A., Siilin, N., Wang, Z., & HEALTHY SAILING project (2025). Monitoring of indoor air quality at a large sailing cruise ship to assess ventilation performance and disease transmission risk. Science of The Total Environment. https://doi.org/10.1016/j.scitotenv.2024.178286

Vancouver

Cheung HYW, Kumar P, Hama S, Emygdio APM, Wei Y, Anagnostopoulos L, et al. Monitoring of indoor air quality at a large sailing cruise ship to assess ventilation performance and disease transmission risk. Science of The Total Environment. 2025. doi:10.1016/j.scitotenv.2024.178286

BibTeX
@article{Cheung2025,
  author = {Cheung, Ho Yin Wickson and Kumar, Prashant and Hama, Sarkawt and Emygdio, Ana Paula Mendes and Wei, Yingyue and Anagnostopoulos, Lemonia and Ewer, John and Ferracci, Valerio and Galea, Edwin R and Grandison, Angus and Hadjichristodoulou, Christos and Jia, Fuchen and Lepore, Pierfrancesco and Morawska, Lidia and Mouchtouri, Varvara A and Siilin, Niko and Wang, Zhaozhi and HEALTHY SAILING project, HEALTHY SAILING project},
  title = {Monitoring of indoor air quality at a large sailing cruise ship to assess ventilation performance and disease transmission risk},
  journal = {Science of The Total Environment},
  year = {2025},
  doi = {10.1016/j.scitotenv.2024.178286}
}
Kostenlos starten →