EUVIMEDEUVIMED entdecken
Crossref

SnO2/GO coated SPR optical fiber sensor for acetone detection in diabetes management: Experimental and theoretical studies

A Prasanth, S Narasimman, M Velumani, Z C Alex

Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2026-03 · 348 · 127209

DOI: 10.1016/j.saa.2025.127209 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2026-03. Verfasst von A Prasanth und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Sensor and Biomedical Technology, School of Electronics Engineering, Vellore Institute of Technology, Vellore 632 014, India; Departmen…. Hauptthemen laut MEDLINE: Acetone, Surface Plasmon Resonance, Tin Compounds, Graphite. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 55 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Acetone in exhaled breath serves as a non-invasive biomarker of diabetes, with levels increasing in proportion to disease severity. We developed a surface plasmon resonance (SPR)-based fiber optic sensor to detect clinically relevant acetone concentrations. Theoretical optimization was carried out to determine the optimal thicknesses of functional layers and sensing parameters prior to fabrication. Two sensor designs were realized: one with a silver/tin oxide configuration (SP1), and another enhanced with a graphene oxide layer (SP2) for improved performance. SP2 demonstrated a higher sensitivity of 0.83 nm/ppm and a maximum resonance wavelength shift of 42 nm at 50 ppm acetone, compared to 0.44 nm/ppm and 22 nm for SP1. It also exhibited faster response/recovery times, as well as reliable detection down to 800 ppb. These proof-of-concept findings highlight the sensor's potential for real-time, non-invasive monitoring of diabetes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AcetoneSurface Plasmon ResonanceTin CompoundsGraphiteOptical FibersDiabetes MellitusHumansLimit of DetectionBreath Tests

Stichwörter der Autor:innen

Acetone biomarkerDiabetes applicationExhaled breathSnO(2)/GO layerSurface plasmon resonance

Substanzen

AcetoneTin CompoundsGraphitestannic oxidegraphene oxide

Autor:innen und Institutionen

  • Department of Sensor and Biomedical Technology, School of Electronics Engineering, Vellore Institute of Technology, Vellore 632 014, India; Department of Optical and Biophysical System, Division of Optics, FZU Institute…
  • Department of Sensor and Biomedical Technology, School of Electronics Engineering, Vellore Institute of Technology, Vellore 632 014, India; Department of Electronics and Communication Engineering, Sri Ramachandra Facult…
  • Department of CSE-Cyber Security & IOT, Sri Ramachandra Faculty of Engineering and Technology, SRIHER, Porur, Chennai, India.
  • Department of Sensor and Biomedical Technology, School of Electronics Engineering, Vellore Institute of Technology, Vellore 632 014, India. Electronic address: zcalex@gmail.com.

Zitieren

APA

Prasanth, A., Narasimman, S., Velumani, M., & Alex, Z. C. (2026). SnO2/GO coated SPR optical fiber sensor for acetone detection in diabetes management: Experimental and theoretical studies. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 348, 127209. https://doi.org/10.1016/j.saa.2025.127209

Vancouver

Prasanth A, Narasimman S, Velumani M, Alex ZC. SnO2/GO coated SPR optical fiber sensor for acetone detection in diabetes management: Experimental and theoretical studies. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2026;348:127209. doi:10.1016/j.saa.2025.127209

BibTeX
@article{Prasanth2026,
  author = {Prasanth, A and Narasimman, S and Velumani, M and Alex, Z C},
  title = {SnO2/GO coated SPR optical fiber sensor for acetone detection in diabetes management: Experimental and theoretical studies},
  journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
  year = {2026},
  volume = {348},
  pages = {127209},
  doi = {10.1016/j.saa.2025.127209}
}
Kostenlos starten →