High-recall calibration monitoring for stereo cameras

Jaroslav Moravec, Radim Šára

Pattern Analysis and Applications · 2024-06 · 27 (2)

DOI: 10.1007/s10044-024-01264-1 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pattern Analysis and Applications, online erschienen am 13.04.2024. Verfasst von Jaroslav Moravec und 1 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Technology Agency of the Czech Republic, Czech Technical University in Prague.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cameras are the prevalent sensors used for perception in autonomous robotic systems, but their initial calibration may degrade over time due to dynamic factors. This may lead to a failure of downstream tasks, such as simultaneous localization and mapping (SLAM) or object recognition. Hence, a computationally lightweight process that detects the decalibration is of interest. We describe a modification of StOCaMo, an online calibration monitoring procedure for a stereoscopic system. The method uses robust kernel correlation based on epipolar constraints; it validates extrinsic calibration parameters on a single frame with no temporal tracking. In this paper, we present a modified StOCaMo with an improved recall rate on small decalibrations through a confirmation technique based on resampled variance. With fixed parameters learned on a realistic synthetic dataset from CARLA, StOCaMo and its proposed modification were tested on multiple sequences from two real-world datasets: KITTI and EuRoC MAV. The modification improved the recall of StOCaMo by 25 % (to 91 % and 82 %, respectively), and the accuracy by 12 % (to 94.7 % and 87.5 %, respectively), while labeling at most one-third of the input data as uninformative. The upgraded method achieved the rank correlation between StOCaMo V-index and downstream SLAM error of 0.78 (Spearman).

Förderung

  • Technology Agency of the Czech Republic
  • Czech Technical University in Prague

Zitieren

APA

Moravec, J., & Šára, R. (2024). High-recall calibration monitoring for stereo cameras. Pattern Analysis and Applications, 27(2). https://doi.org/10.1007/s10044-024-01264-1

Vancouver

Moravec J, Šára R. High-recall calibration monitoring for stereo cameras. Pattern Analysis and Applications. 2024;27(2). doi:10.1007/s10044-024-01264-1

BibTeX
@article{Moravec2024,
  author = {Moravec, Jaroslav and Šára, Radim},
  title = {High-recall calibration monitoring for stereo cameras},
  journal = {Pattern Analysis and Applications},
  year = {2024},
  volume = {27},
  number = {2},
  doi = {10.1007/s10044-024-01264-1}
}
Kostenlos starten →