EUVIMEDEUVIMED entdecken
Crossref

Selective recognition of fluoride as a CBRN toxic agent by a non-symmetric pillar[5]arene and Bodipy combination

Cumali Karatutlu, Ahmed Nuri Kursunlu

Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2025

DOI: 10.1016/j.saa.2025.126506 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2025. Verfasst von Cumali Karatutlu und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Private Security and Protection, Suluova Vocational School, Amasya University, Amasya, Turkey; Department of Chemical Biological Radiol…. Hauptthemen laut MEDLINE: Fluorides, Boron Compounds, Calixarenes, Fluorescent Dyes. Die Arbeit nennt 50 Literaturangaben. Gefördert von: Selçuk Üniversitesi.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The CBRN (chemical, biological, radiological and nuclear) materials caused to serious health risks that the effective detection of these agents is very important. Macrocyclic fluorescent sensors based on Pillar[5]arene bearing multi Bodipy units have been designed for toxic agents in the CBRN area. The prepared non-symmetric Pillar[5]arene derivative (Pillar[5]-Bodipys) was characterized by NMR, elemental analysis, FT-IR and melting point methods. The macrocyclic sensor exhibits a strong emission around 510 nm, which is used to monitor the interaction of toxic anions. Ion-binding experiments of the chemosensor have been examined in half-aqueous medium with a wide range of anions and the detection process is monitored by UV-vis and fluorescence spectroscopies. The results demonstrated that the chemosensor, Pillar[5]-Bodipys, has a sensitivity and selectivity toward toxic F- ion. The fluorescence intensity of Pillar[5]-Bodipys quenched significantly in the presence of F- anion and LOD was determined as 2.1x10-7 M. In the detection of F- ion, Pillar[5]-Bodipys has also an ideal response time and good stability in a range of pH's. The biological imaging was examined for the detection of F- ion by Pillar[5]-Bodipys, that the fluorescent macrocyclic sensor has a low toxicity. It can be successfully used in the recognition of F- ions on living cells.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

FluoridesBoron CompoundsCalixarenesFluorescent DyesQuaternary Ammonium CompoundsSpectrometry, FluorescenceHumansSpectroscopy, Fourier Transform InfraredSpectrophotometry, Ultraviolet

Stichwörter der Autor:innen

BodipyFluorescent sensorFluorideMacroringPillar[5]arene

Substanzen

Fluorides4,4-difluoro-4-bora-3a,4a-diaza-s-indaceneBoron Compoundspillar(5)areneCalixarenesFluorescent DyesQuaternary Ammonium Compounds

Autor:innen und Institutionen

  • Department of Private Security and Protection, Suluova Vocational School, Amasya University, Amasya, Turkey; Department of Chemical Biological Radiology and Nuclear Defense, Health Sciences Institute University of Selcu…
  • Department of Chemistry, Faculty of Science, University of Selcuk, Konya, Turkey. Electronic address: ankursunlu@gmail.com.

Förderung

  • Selçuk Üniversitesi

Zitieren

APA

Karatutlu, C., & Kursunlu, A. N. (2025). Selective recognition of fluoride as a CBRN toxic agent by a non-symmetric pillar[5]arene and Bodipy combination. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. https://doi.org/10.1016/j.saa.2025.126506

Vancouver

Karatutlu C, Kursunlu AN. Selective recognition of fluoride as a CBRN toxic agent by a non-symmetric pillar[5]arene and Bodipy combination. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2025. doi:10.1016/j.saa.2025.126506

BibTeX
@article{Karatutlu2025,
  author = {Karatutlu, Cumali and Kursunlu, Ahmed Nuri},
  title = {Selective recognition of fluoride as a CBRN toxic agent by a non-symmetric pillar[5]arene and Bodipy combination},
  journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
  year = {2025},
  doi = {10.1016/j.saa.2025.126506}
}
Kostenlos starten →