Novel Anthracene‐Appended Calix[4]triazacrown‐5 as an Effective Fluorescence Probe for Co 2+ and Hazardous Cr 2 O 7 2− Ions

Serkan Sayin iD

Luminescence · 2024

DOI: 10.1002/bio.4920 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Luminescence, 2024. Verfasst von Serkan Sayin. Beteiligte Einrichtung: Department of Environmental Engineering, Giresun University, Giresun, Turkey. Hauptthemen laut MEDLINE: Anthracenes, Fluorescent Dyes, Calixarenes, Cobalt. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: Research Foundation of Giresun University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A new calix[4]triazacrown‐5–derived fluorescence chemosensor ( AntUr‐AzClx ) at cone conformation was synthesized to afford an effective fluorescent probe, which enables an enhancement in the fluorescence intensity specifically in the presence of Co 2+ metal ions as well as a turnoff response for hazardous dichromate anions. 1 H‐NMR, 13 C‐NMR, ESI‐MS, and elemental analysis techniques were used to characterize the structure of the anthracene‐appended calix[4]triazacrown‐5 ( AntUr‐AzClx ). The metal ion–binding ability of AntUr‐AzClx was evaluated against Co 2+ , Ba 2+ , Ni 2+ , Pb 2+ , and Zn 2+ ions. On the basis of various metal ion recognition phenomena, AntUr‐AzClx exhibited outstanding selectivity for only the Co 2+ ion among other metal ions. Also, the calix[4]triazacrown‐5–derived fluorescence chemosensor showed high sensitivity towards the Co 2+ ion with a very low limit of detection (LOD) 0.142 μmol L −1 . In addition, anion binding abilities of AntUr‐AzClx against various anions such Cr 2 O 7 2− , HCO 3 − , CO 3 2− , NO 3 − , SO 3 2− , SO 4 2− , N 3 − , F − , and I − demonstrated that AntUr‐AzClx enables selective and highly sensitive detection of the Cr 2 O 7 2− anion with an excellent LOD of 4.182 nmol L −1 in DMF/PBS (1/1, v/v; pH: 7.05). Furthermore, the calix[4]triazacrown‐5–derived fluorescence chemosensor displayed a significant sensing behavior to detect the presence of dichromate anions even in real samples.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AnthracenesFluorescent DyesCalixarenesCobaltSpectrometry, FluorescenceMolecular StructureChromiumIonsLimit of Detection

Stichwörter der Autor:innen

Co2+ detectioncalixarenedichromate anion detectionfluorescence chemosensorsynthesis

Substanzen

AnthracenesFluorescent DyesCalixarenesCobaltanthraceneChromiumIons

Autor:innen und Institutionen

  • Department of Environmental Engineering, Giresun University, Giresun, Turkey.

ORCID-Profile: Serkan Sayin

Förderung

  • Research Foundation of Giresun University

Zitieren

APA

Sayin, S. (2024). Novel Anthracene‐Appended Calix[4]triazacrown‐5 as an Effective Fluorescence Probe for Co 2+ and Hazardous Cr 2 O 7 2− Ions. Luminescence. https://doi.org/10.1002/bio.4920

Vancouver

Sayin S. Novel Anthracene‐Appended Calix[4]triazacrown‐5 as an Effective Fluorescence Probe for Co 2+ and Hazardous Cr 2 O 7 2− Ions. Luminescence. 2024. doi:10.1002/bio.4920

BibTeX
@article{Sayin2024,
  author = {Sayin, Serkan},
  title = {Novel Anthracene‐Appended Calix[4]triazacrown‐5 as an Effective Fluorescence Probe for Co 2+ and Hazardous Cr 2 O 7 2− Ions},
  journal = {Luminescence},
  year = {2024},
  doi = {10.1002/bio.4920}
}
Kostenlos starten →