An enzyme-free self-cascade catalytic dual-read biosensor for noninvasive detection of glucose based on oxidase-mimic Fe-MOF

Xiulin Wang, Ziyi Guo, Tao Lian, Xiaomin Tang, Ping Qiu

Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2025

DOI: 10.1016/j.saa.2025.126334 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2025. Verfasst von Xiulin Wang und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry and Chemical Engineering, Nanchang University, Nanchang 330031, China. Hauptthemen laut MEDLINE: Metal-Organic Frameworks, Glucose Oxidase, Biosensing Techniques, Glucose. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 63 Literaturangaben. Gefördert von: Nanchang University, State Key Laboratory of Food Science and Resources, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Metal-organic framework (MOF) materials have attracted much attention in the glucose detection owing to their high porosity and diverse catalytic sites. In this study, we synthesized Fe-MOF material with both glucose oxidase (GOD) activity and peroxidase (POD)-like activity. Mechanistically, Fe-MOF with GOD activity catalyze decomposition of glucose into H2O2 and gluconic acid, which self-cascade catalysis catalyze H2O2 decomposition to yield hydroxyl radical (•OH) by means of POD activity. •OH can oxidize the chromogenic substrate o-phenylenediamine (OPD) to yellow product 2,3-diaminophenazine (DAP), which causes strong absorption of the UV visible spectrum at 450 nm. Concurrently, a distinct fluorescence emission peak emerges at 565 nm and the intrinsic fluorescence of Fe-MOF at 465 nm exhibits fluorescence resonance energy transfer (FRET)-mediated quenching. Therefore, a dual-read biosensor for the quantification of glucose was proposed based on Fe-MOF with the aid of colorimetric and ratiometric fluorescence signals of I565/I465. The LOD was as low as 0.71 μM and 0.69 μM, respectively. Satisfactory recovery and low relative standard deviation were achieved in real human saliva samples.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Metal-Organic FrameworksGlucose OxidaseBiosensing TechniquesGlucoseIronHumansCatalysisHydrogen PeroxideLimit of DetectionFluorescence Resonance Energy TransferColorimetrySpectrometry, Fluorescence

Stichwörter der Autor:innen

Cascade catalysisDual-mode sensorGlucose oxidaseMOF

Substanzen

Metal-Organic FrameworksGlucose OxidaseGlucoseIronHydrogen Peroxide

Autor:innen und Institutionen

  • School of Chemistry and Chemical Engineering, Nanchang University, Nanchang 330031, China.
  • School of Chemistry and Chemical Engineering, Nanchang University, Nanchang 330031, China; State Key Laboratory of Food Science and Resources, Nanchang University, Nanchang 330047, China.
  • Affiliated Rehabilitation Hospital of Nanchang University, Nanchang 330003, China. Electronic address: ndsfy00395@ncu.edu.cn.
  • School of Chemistry and Chemical Engineering, Nanchang University, Nanchang 330031, China; State Key Laboratory of Food Science and Resources, Nanchang University, Nanchang 330047, China. Electronic address: pingqiu@ncu…

Förderung

  • Nanchang University
  • State Key Laboratory of Food Science and Resources
  • National Natural Science Foundation of China

Zitieren

APA

Wang, X., Guo, Z., Lian, T., Tang, X., & Qiu, P. (2025). An enzyme-free self-cascade catalytic dual-read biosensor for noninvasive detection of glucose based on oxidase-mimic Fe-MOF. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. https://doi.org/10.1016/j.saa.2025.126334

Vancouver

Wang X, Guo Z, Lian T, Tang X, Qiu P. An enzyme-free self-cascade catalytic dual-read biosensor for noninvasive detection of glucose based on oxidase-mimic Fe-MOF. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2025. doi:10.1016/j.saa.2025.126334

BibTeX
@article{Wang2025,
  author = {Wang, Xiulin and Guo, Ziyi and Lian, Tao and Tang, Xiaomin and Qiu, Ping},
  title = {An enzyme-free self-cascade catalytic dual-read biosensor for noninvasive detection of glucose based on oxidase-mimic Fe-MOF},
  journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
  year = {2025},
  doi = {10.1016/j.saa.2025.126334}
}
Kostenlos starten →