Sensitive determination of prostate-specific antigen with graphene quantum dot-based fluorescence aptasensor using few-layer V2CTx MXene as quencher
Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2023-05 · 293 · 122474
DOI: 10.1016/j.saa.2023.122474 ↗Kurz gefasst
Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2023-05. Verfasst von Tianyi Zhu und 8 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry and Life Sciences, Zhejiang Normal University, Jinhua 321004, PR China; Jiaxing Key Laboratory of Molecular Recognition and Sens…. Hauptthemen laut MEDLINE: Quantum Dots, Graphite, Aptamers, Nucleotide, Biosensing Techniques. Die Arbeit wurde bisher 27-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Zhejiang Province Public Welfare Technology Application Research Project.
Abstract (Originalsprache)
A novel fluorescence aptasensor of prostate-specific antigen (PSA) was established using few-layer vanadium carbide (FL-V2CTx) nanosheet as a quencher. First, FL-V2CTx was prepared by the delamination of multi-layer V2CTx (ML-V2CTx) with tetramethylammonium hydroxide. The aptamer-carboxyl graphene quantum dots (CGQDs) probe was prepared by combining the aminated PSA aptamer and CGQDs. Then, the aptamer-CGQDs were absorbed onto the surface of FL-V2CTx by hydrogen bond interaction, which led to the decrease in fluorescence of aptamer-CGQDs due to photoinduced energy transfer. After addition of PSA, PSA-aptamer-CGQDs complex was released from FL-V2CTx. The fluorescence intensity of aptamer-CGQDs-FL-V2CTx with PSA was higher than that without PSA. The FL-V2CTx-based fluorescence aptasensor provided a PSA detection linear range from 0.1 to 20 ng mL-1 with detection limit of 0.03 ng mL-1. The ΔF value of fluorescence intensities for aptamer-CGQDs-FL-V2CTx with and without PSA was 5.6, 3.7, 7.7, and 5.4 times of ML-V2CTx, few-layer titanium carbide (FL-Ti3C2Tx), ML-Ti3C2Tx and graphene oxide aptasensors, respectively, indicating the advantage of FL-V2CTx. The aptasensor had high selectivity for PSA detection compared with some proteins and tumor markers. This proposed method had convenience and high sensitivity for PSA determination. The determination results of PSA in human serum samples using the aptasensor were consistent with those by chemiluminescent immunoanalysis. The fluorescence aptasensor can be successfully applied for PSA determination in serum samples of prostate cancer patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- College of Chemistry and Life Sciences, Zhejiang Normal University, Jinhua 321004, PR China; Jiaxing Key Laboratory of Molecular Recognition and Sensing, College of Biological, Chemical Sciences and Engineering, Jiaxing…
- Clinical Laboratory of Zhejiang Sian International Hospital, Jiaxing 314000, PR China.
- Jiaxing Key Laboratory of Molecular Recognition and Sensing, College of Biological, Chemical Sciences and Engineering, Jiaxing University, Jiaxing 314001, PR China. Electronic address: ybzeng@mail.zjxu.edu.cn.
- Jiaxing Key Laboratory of Molecular Recognition and Sensing, College of Biological, Chemical Sciences and Engineering, Jiaxing University, Jiaxing 314001, PR China.
- College of Chemistry and Life Sciences, Zhejiang Normal University, Jinhua 321004, PR China. Electronic address: cjr@zjnu.cn.
- Jiaxing Key Laboratory of Molecular Recognition and Sensing, College of Biological, Chemical Sciences and Engineering, Jiaxing University, Jiaxing 314001, PR China. Electronic address: lei.li@mail.zjxu.edu.cn.
Förderung
- National Natural Science Foundation of China
- Zhejiang Province Public Welfare Technology Application Research Project
Zitieren
APA
Zhu, T., Tang, Q., Zeng, Y., Chen, S., Yang, Y., Wang, H., Chen, J., Guo, L., & Li, L. (2023). Sensitive determination of prostate-specific antigen with graphene quantum dot-based fluorescence aptasensor using few-layer V2CTx MXene as quencher. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 293, 122474. https://doi.org/10.1016/j.saa.2023.122474
Vancouver
Zhu T, Tang Q, Zeng Y, Chen S, Yang Y, Wang H, et al. Sensitive determination of prostate-specific antigen with graphene quantum dot-based fluorescence aptasensor using few-layer V2CTx MXene as quencher. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2023;293:122474. doi:10.1016/j.saa.2023.122474
BibTeX
@article{Zhu2023,
author = {Zhu, Tianyi and Tang, Qiukai and Zeng, Yanbo and Chen, Shijie and Yang, Yiwen and Wang, Hailong and Chen, Jianrong and Guo, Longhua and Li, Lei},
title = {Sensitive determination of prostate-specific antigen with graphene quantum dot-based fluorescence aptasensor using few-layer V2CTx MXene as quencher},
journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
year = {2023},
volume = {293},
pages = {122474},