Tuning quantum dots emission on DNA tetrahedron/silica nanosphere/graphene oxide nanointerface for ratiometric fluorescence assay of Pb2+ in multiplex samples
Analytica Chimica Acta · 2024
DOI: 10.1016/j.aca.2024.342716 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024. Verfasst von Manting Li und 7 weiteren Autor:innen. Beteiligte Einrichtung: Guangxi Key Laboratory of Pharmaceutical Precision Detection and Screening, Pharmaceutical College, Guangxi Medical University, 22 Shuangyong Road, N…. Hauptthemen laut MEDLINE: Quantum Dots, Lead, Graphite, Silicon Dioxide. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 81 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
BACKGROUND: Assembling framework nucleic acid (FNA) nanoarchitectures and tuning luminescent quantum dots (QDs) for fluorescence assays represent a versatile strategy in analytical territory. Rationally, FNA constructs could offer a preferential orientation to efficiently recognize the target and improve detection sensitivity, meanwhile, regulating size-dependent multicolor emissions of QDs in one analytical setting for ratiometric fluorescence assay would greatly simplify operation procedures. Nonetheless, such FNA/QDs-based ratiometric fluorescence nanoprobes remain rarely explored. RESULTS: We designed a sensitive and signal amplification-free fluorescence aptasensor for lead ions (Pb2+) that potentially cause extensive contamination to environment, cosmetic, food and pharmaceuticals. Red and green emission CdTe quantum dots (rQDs and gQDs) were facilely prepared. Moreover, silica nanosphere encapsulating rQDs served as quantitative internal reference and scaffold to anchor a predesigned FNA and DNA sandwich containing Pb2+ binding aptamer and gQD modified DNA signal reporter. On binding of Pb2+, the gQD-DNA signal reporter was set free, resulting in fluorescence quenching at graphene oxide (GO) interface. Owing to the rigid structure of FNA, the fluorescence signal reporter orderly arranged at the silica nanosphere could sensitively respond to Pb2+ stimulation. The dose-dependent fluorescence signal-off mode enabled ratiometric analysis of Pb2+ without cumbersome signal amplification. Linear relationship was established between fluorescence intensity ratio (I555/I720) and Pb2+ concentration from 10 nM to 2 μM, with detection limit of 1.7 nM (0.43 ppb), well addressing the need for Pb2+ routine monitoring. The designed nanoprobe was applied to detection of Pb2+ in soil, cosmetic, milk, drug, and serum samples, with the sensitivity comparable to conventional ICP-MS technique. SIGNIFICANCE: Given the programmable design of FNA and efficient recognition of target, flexible tuning of QDs emission, and signal amplification-free strategy, the present fluorescence nanoprobe could be a technical criterion for other heavy metal ions detection in a straightforward manner.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Guangxi Key Laboratory of Pharmaceutical Precision Detection and Screening, Pharmaceutical College, Guangxi Medical University, 22 Shuangyong Road, Nanning 530021, China; Key Laboratory of Micro-Nanoscale Bioanalysis an…
- Guangxi Key Laboratory of Pharmaceutical Precision Detection and Screening, Pharmaceutical College, Guangxi Medical University, 22 Shuangyong Road, Nanning 530021, China.
- Guangxi Key Laboratory of Pharmaceutical Precision Detection and Screening, Pharmaceutical College, Guangxi Medical University, 22 Shuangyong Road, Nanning 530021, China. Electronic address: maoyuang@gxmu.edu.cn.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Li, M., Luo, H., Wang, Z., Mo, Q., Zhong, S., Mao, Y. A., Li, S., & Li, X. (2024). Tuning quantum dots emission on DNA tetrahedron/silica nanosphere/graphene oxide nanointerface for ratiometric fluorescence assay of Pb2+ in multiplex samples. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2024.342716
Vancouver
Li M, Luo H, Wang Z, Mo Q, Zhong S, Mao YA, et al. Tuning quantum dots emission on DNA tetrahedron/silica nanosphere/graphene oxide nanointerface for ratiometric fluorescence assay of Pb2+ in multiplex samples. Analytica Chimica Acta. 2024. doi:10.1016/j.aca.2024.342716
BibTeX
@article{Li2024,
author = {Li, Manting and Luo, Haikun and Wang, Zhao and Mo, Qian and Zhong, Shanshan and Mao, Yu-Ang and Li, Shuting and Li, Xinchun},
title = {Tuning quantum dots emission on DNA tetrahedron/silica nanosphere/graphene oxide nanointerface for ratiometric fluorescence assay of Pb2+ in multiplex samples},
journal = {Analytica Chimica Acta},
year = {2024},
doi = {10.1016/j.aca.2024.342716}
}