Impaired thrombin generation as a reproducible feature of bleeding disorder of unknown cause
Research and Practice in Thrombosis and Haemostasis · 2026-03 · 10 (3) · 103451
DOI: 10.1016/j.rpth.2026.103451 ↗Kurz gefasst
Fachartikel in der Zeitschrift Research and Practice in Thrombosis and Haemostasis, 2026-03. Verfasst von Tim Dreier und 6 weiteren Autor:innen. Beteiligte Einrichtung: Division of Hematology and Hemostaseology, Department of Medicine I, Medical University of Vienna, Vienna, Austria. Hauptthemen laut MEDLINE: Thrombin, Blood Coagulation Disorders. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: CSL Behring.
Abstract (Originalsprache)
Background
Thrombin generation (TG) has previously been investigated in patients with bleeding disorder of unknown cause (BDUC) with discrepant results.
Objective
To investigate whether previously reported impairments of TG in BDUC patients can be resproduced using a automated TG analysed at different tissue factor concentrations.
Methods
In this case-control cohort study, TG was measured in patients with BDUC and age- and sex-matched healthy controls using the fully automated Ceveron S100 assay with 2 trigger reagents: reagent B (RB; very low tissue factor concentration) and reagent C-low (RC; low tissue factor concentration).
Results
In total, 62 patients and 22 controls were analyzed. In both reagents, patients compared with healthy controls had longer time to peak (RB: 16.2 vs 12.8 seconds; RC-low: 10.3 vs 8.5 seconds; P < .001), lower peak thrombin (RB: 209.0 vs 300.7 nM; P < .001; RC-low: 243.6 vs 299.2 nM; P = .011), and lastly a lower velocity index (RB: 25.6 vs 45.9 nM/min; P < .001; RC-low: 34.6 vs 54.3 nM/min; P = .001). The lag time was only significantly prolonged in patients in RB (7.6 vs 6.1 seconds; P < .001), but not with RC-low (3.2 vs 3.0 seconds; P = .403), as was the area under the curve (RB: 2776.9 vs 3276.3 nM × min; P < .001; RC-low: 2824.7 vs 2842.7 nM × min; P = .072). Crossvalidated receiver operating characteristic analysis showed an area under the curve of 0.74 (95% CI, 0.62-0.86) for RB and 0.76 (95% CI, 0.65-0.87) for RC-low. However, there was no association between the bleeding score and any TG parameters after adjustment for factor [F]VIII and FIX activity.
Conclusion
This study highlights the reproducibility of impaired TG in patients with BDUC. Given that BDUC pathophysiology remains largely unknown, these findings suggest impaired TG may represent a common underlying feature of BDUC and underscore the need for further validation in independent cohorts and clinical settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Division of Hematology and Hemostaseology, Department of Medicine I, Medical University of Vienna, Vienna, Austria.
- Department of Laboratory Medicine, Medical University of Vienna, Vienna, Austria.
Förderung
- CSL Behring
Zitieren
APA
Dreier, T., Mehic, D., Oosterlee, J., Haslacher, H., Ay, C., Pabinger, I., & Gebhart, J. (2026). Impaired thrombin generation as a reproducible feature of bleeding disorder of unknown cause. Research and Practice in Thrombosis and Haemostasis, 10(3), 103451. https://doi.org/10.1016/j.rpth.2026.103451
Vancouver
Dreier T, Mehic D, Oosterlee J, Haslacher H, Ay C, Pabinger I, et al. Impaired thrombin generation as a reproducible feature of bleeding disorder of unknown cause. Research and Practice in Thrombosis and Haemostasis. 2026;10(3):103451. doi:10.1016/j.rpth.2026.103451
BibTeX
@article{Dreier2026,
author = {Dreier, Tim and Mehic, Dino and Oosterlee, Justin and Haslacher, Helmut and Ay, Cihan and Pabinger, Ingrid and Gebhart, Johanna},
title = {Impaired thrombin generation as a reproducible feature of bleeding disorder of unknown cause},
journal = {Research and Practice in Thrombosis and Haemostasis},
year = {2026},
volume = {10},
number = {3},
pages = {103451},
doi = {10.1016/j.rpth.2026.103451}
}
EUVIMED