Establishing the clinical utility of integrated quasistatic acoustic tweezing thromboelastometry for blood coagulation analysis
Journal of Thrombosis and Haemostasis · 2026
DOI: 10.1016/j.jtha.2025.12.020 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Journal of Thrombosis and Haemostasis, 2026. Verfasst von Huy Q Pham und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Tulane University, New Orleans, Louisiana, USA. Electronic address: https://x.com/HuyPham95096. Hauptthemen laut MEDLINE: Thrombelastography, Blood Coagulation, Blood Coagulation Disorders, Acoustics. Die Arbeit nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, National Institutes of Health, National Science Foundation.
Abstract (Originalsprache)
BACKGROUND: Rapid and accurate coagulation analysis is essential for managing critical care and surgical patients, patients with coagulation disorders, and patients with cardiovascular disease on anticoagulant therapy. Traditional assays often require large sample volumes, posing iatrogenic risks in vulnerable populations, including pediatric and elderly patients. Integrated quasistatic acoustic tweezing thromboelastometry (i-QATT) offers a comprehensive, noncontact assessment of coagulation using a 4- to 6-μL drop of blood that minimizes diagnostic errors associated with sample-container surface interactions. OBJECTIVES: This study aims to assess the preliminary clinical utility of the i-QATT technique. METHODS: Using blood samples from healthy volunteers and liver transplant patients, as well as control plasmas, we established the reference ranges for i-QATT coagulation parameters and validated them across several abnormal conditions, including single-factor deficiencies, abnormal fibrinogen levels, unfractionated heparin anticoagulation, and coagulopathy. RESULTS: i-QATT identified coagulation abnormalities within 3 to 8 minutes. Its parameters showed strong correlations with gold-standard assay data, for example, activated partial thromboplastin time (r ≥ 0.81), international normalized ratio (r ≥ 0.74), thromboelastography (TEG) citrated kaolin channel parameters (R, K, α, and maximum width of TEG tracing [MA]; r ≥ 0.65), citrated rapid TEG (MA; r = 0.64), and TEG citrated functional fibrinogen (MA; r ≥ 0.64). i-QATT data demonstrated a near-linear response to unfractionated heparin concentrations spanning the prophylactic and therapeutic ranges (0-1 IU/mL; R2 = 0.98), and the anticoagulation reversal by heparinase was reliably detected. i-QATT accurately assessed the functional level of fibrinogen and platelet activity in normal and abnormal blood samples. CONCLUSIONS: This study positions i-QATT as a highly sensitive, rapid, and ultra-low-volume alternative to conventional coagulation assays, with strong potential to transform point-of-care diagnostics across a wide range of clinical settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Biomedical Engineering, Tulane University, New Orleans, Louisiana, USA. Electronic address: https://x.com/HuyPham95096.
- Department of Biomedical Engineering, Tulane University, New Orleans, Louisiana, USA.
- Department of Anesthesiology and Perioperative Medicine, Ochsner Medical Center, New Orleans, Louisiana, USA.
- Department of Biomedical Engineering, Tulane University, New Orleans, Louisiana, USA; Levisonics Inc, New Orleans, Louisiana, USA. Electronic address: damir@tulane.edu.
Förderung
- NIBIB NIH HHS
- National Institutes of Health
- National Science Foundation
Zitieren
APA
Pham, H. Q., Barnor, C., Paul, T., Cummins, E. M., Arango, D., Yockelson, S., & Khismatullin, D. B. (2026). Establishing the clinical utility of integrated quasistatic acoustic tweezing thromboelastometry for blood coagulation analysis. Journal of Thrombosis and Haemostasis. https://doi.org/10.1016/j.jtha.2025.12.020
Vancouver
Pham HQ, Barnor C, Paul T, Cummins EM, Arango D, Yockelson S, et al. Establishing the clinical utility of integrated quasistatic acoustic tweezing thromboelastometry for blood coagulation analysis. Journal of Thrombosis and Haemostasis. 2026. doi:10.1016/j.jtha.2025.12.020
BibTeX
@article{Pham2026,
author = {Pham, Huy Q and Barnor, Collette and Paul, Trishita and Cummins, Elizabeth M and Arango, Daniel and Yockelson, Shaun and Khismatullin, Damir B},
title = {Establishing the clinical utility of integrated quasistatic acoustic tweezing thromboelastometry for blood coagulation analysis},
journal = {Journal of Thrombosis and Haemostasis},
year = {2026},
doi = {10.1016/j.jtha.2025.12.020}
}
EUVIMED