E-MARA: An electrohysterogram motion artifact rejection algorithm
Results in Engineering · 2026-12 · 32 · 112990
DOI: 10.1016/j.rineng.2026.112990 ↗Kurz gefasst
Fachartikel in der Zeitschrift Results in Engineering, 2026-12. Verfasst von Hadi Ammar und 5 weiteren Autor:innen. Die Arbeit nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Université Libanaise, Institut National des Sciences Appliquées Lyon, Université de Technologie de Compiègne.
Abstract (Originalsprache)
Predicting the infant’s delivery term is crucial for initiating early clinical interventions for preterm infants. The analysis of electrohysterogram (EHG) signals that drive uterine muscular contractions has proven effective for monitoring the pregnant woman’s uterine activity. However, the accurate analysis depends mainly on the quality of EHG contractions. This paper introduces a new artifact rejection method, the electrohysterogram motion artifact rejection algorithm (E-MARA), designed to remove motion artifacts from EHG contraction bursts, thereby improving signal quality. It also presents a novel bipolar channel selection strategy, which was used for optimizing E-MARA. E-MARA was compared with existing state-of-the-art EHG filtering methods using simulated EHG contractions, followed by validation on real contractions. The gain ( G ) in signal-to-artifact ratio (SAR) and root mean square error ( RMSE ) were used to assess the quality of the processed simulated contractions. For real contractions, the signal-to-noise ratio ( SNR r ) between contractions and the resting periods was calculated. E-MARA achieved a median G of 8.9 dB and a median RMSE of 1.7 μV, yielding promising results on simulated contractions compared with current filtering methods. When applied to real EHG contractions from two databases, E-MARA increased the percentage of positive median SNR r values per woman by 26.4% and 28%, respectively. These results did not differ significantly when E-MARA was applied to fewer EHG electrodes. Overall, the G and RMSE values indicate that E-MARA effectively removes motion artifacts from simulated contractions, and the SNR r improvements demonstrate that it enhances the quality of real contractions.
Förderung
- Université Libanaise
- Institut National des Sciences Appliquées Lyon
- Université de Technologie de Compiègne
Zitieren
APA
Ammar, H., Diab, A., Zalc, V., Istrate, D., Khalil, M., & Marque, C. (2026). E-MARA: An electrohysterogram motion artifact rejection algorithm. Results in Engineering, 32, 112990. https://doi.org/10.1016/j.rineng.2026.112990
Vancouver
Ammar H, Diab A, Zalc V, Istrate D, Khalil M, Marque C. E-MARA: An electrohysterogram motion artifact rejection algorithm. Results in Engineering. 2026;32:112990. doi:10.1016/j.rineng.2026.112990
BibTeX
@article{Ammar2026,
author = {Ammar, Hadi and Diab, Ahmad and Zalc, Vincent and Istrate, Dan and Khalil, Mohamad and Marque, Catherine},
title = {E-MARA: An electrohysterogram motion artifact rejection algorithm},
journal = {Results in Engineering},
year = {2026},
volume = {32},
pages = {112990},
doi = {10.1016/j.rineng.2026.112990}
}
EUVIMED