An Accurate Non-accelerometer-based PPG Motion Artifact Removal Technique using CycleGAN
ACM Transactions on Computing for Healthcare · 31.01.2023 · 4 (1) · 1-14
DOI: 10.1145/3563949 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACM Transactions on Computing for Healthcare, online erschienen am 27.02.2023. Verfasst von Amir Hosein Afandizadeh Zargari und 4 weiteren Autor:innen. Die Arbeit wurde bisher 40-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
A photoplethysmography (PPG) is an uncomplicated and inexpensive optical technique widely used in the healthcare domain to extract valuable health-related information, e.g., heart rate variability, blood pressure, and respiration rate. PPG signals can easily be collected continuously and remotely using portable wearable devices. However, these measuring devices are vulnerable to motion artifacts caused by daily life activities. The most common ways to eliminate motion artifacts use extra accelerometer sensors, which suffer from two limitations: (i) high power consumption, and (ii) the need to integrate an accelerometer sensor in a wearable device (which is not required in certain wearables). This paper proposes a low-power non-accelerometer-based PPG motion artifacts removal method outperforming the accuracy of the existing methods. We use Cycle Generative Adversarial Network to reconstruct clean PPG signals from noisy PPG signals. Our novel machine-learning-based technique achieves 9.5 times improvement in motion artifact removal compared to the state-of-the-art without using extra sensors such as an accelerometer, which leads to 45% improvement in energy efficiency.
Zitieren
APA
Zargari, A. H. A., Aqajari, S. A. H., Khodabandeh, H., Rahmani, A., & Kurdahi, F. (2023). An Accurate Non-accelerometer-based PPG Motion Artifact Removal Technique using CycleGAN. ACM Transactions on Computing for Healthcare, 4(1), 1-14. https://doi.org/10.1145/3563949
Vancouver
Zargari AHA, Aqajari SAH, Khodabandeh H, Rahmani A, Kurdahi F. An Accurate Non-accelerometer-based PPG Motion Artifact Removal Technique using CycleGAN. ACM Transactions on Computing for Healthcare. 2023;4(1):1-14. doi:10.1145/3563949
BibTeX
@article{Zargari2023,
author = {Zargari, Amir Hosein Afandizadeh and Aqajari, Seyed Amir Hossein and Khodabandeh, Hadi and Rahmani, Amir and Kurdahi, Fadi},
title = {An Accurate Non-accelerometer-based PPG Motion Artifact Removal Technique using CycleGAN},
journal = {ACM Transactions on Computing for Healthcare},
year = {2023},
volume = {4},
number = {1},
pages = {1--14},
doi = {10.1145/3563949}
}
EUVIMED