Microdose CT for postlung biopsy pneumothorax detection: A case series
Radiology Case Reports · 2026-12 · 21 (12) · 6919-6927
DOI: 10.1016/j.radcr.2026.10.033 ↗Kurz gefasst
Fallbericht in der Zeitschrift Radiology Case Reports, 2026-12. Verfasst von Abdulrahman Al Bochi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Schulich School of Medicine & Dentistry, Western University, London, Ontario, Canada. Die Arbeit nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Pneumothorax is the most common complication of computed tomography (CT)-guided percutaneous transthoracic biopsy, an important diagnostic procedure in the workup of pulmonary nodules. Timely and accurate detection of pneumothorax postlung biopsy can guide management and prevent further morbidity. We present 3 cases comparing chest radiography (CXR) with microdose CT for detecting postlung biopsy pneumothorax. In each case, microdose CT resulted in diagnostically sufficient images with effective dose ranges of 0.0417-0.0538 mSv, corresponding to an effective dose range of approximately 2.5 CXRs. In case 3, a small loculated pneumothorax not readily apparent on CXR was more easily appreciated on microdose CT. This case series highlights a novel real-world clinical application of microdose CT for postbiopsy pneumothorax detection which has not been well documented previously that warrants prospective evaluation. Studies are needed to assess microdose CT diagnostic accuracy, feasibility, and clinical impact when used in a postbiopsy procedural setting.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Schulich School of Medicine & Dentistry, Western University, London, Ontario, Canada.
- Department of Interventional Radiology, Imaging Institute, Cleveland Clinic, Cleveland, OH, USA.
- Department of Diagnostic Imaging, Bluewater Health, Sarnia, Ontario, Canada.
- Faculty of Mathematics, University of Waterloo, Waterloo, Ontario, Canada.
- Department of Human Health Sciences, University of Guelph, Guelph, Ontario, Canada.
Zitieren
APA
Al Bochi, A., Abou Shaar, B., Munir, S., Almalki, N., Alkassem, Z., & Almalki, Y. (2026). Microdose CT for postlung biopsy pneumothorax detection: A case series. Radiology Case Reports, 21(12), 6919-6927. https://doi.org/10.1016/j.radcr.2026.10.033
Vancouver
Al Bochi A, Abou Shaar B, Munir S, Almalki N, Alkassem Z, Almalki Y. Microdose CT for postlung biopsy pneumothorax detection: A case series. Radiology Case Reports. 2026;21(12):6919-6927. doi:10.1016/j.radcr.2026.10.033
BibTeX
@article{AlBochi2026,
author = {Al Bochi, Abdulrahman and Abou Shaar, Bader and Munir, Sohaib and Almalki, Nadeem and Alkassem, Zayd and Almalki, Youssef},
title = {Microdose CT for postlung biopsy pneumothorax detection: A case series},
journal = {Radiology Case Reports},
year = {2026},
volume = {21},
number = {12},
pages = {6919--6927},
doi = {10.1016/j.radcr.2026.10.033}
}
EUVIMED