Fachartikel in der Zeitschrift Tomography, online erschienen am 01.07.2026. Verfasst von Nour Afilal und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University of Bern, Rosenbühlgasse 27, 3010 …. Hauptthemen laut MEDLINE: Pneumothorax, Ozone, Tomography, X-Ray Computed, Image-Guided Biopsy. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background/Objectives: To evaluate whether day-of-procedure ambient ozone exposure is associated with pneumothorax after CT-guided lung biopsy.
Methods
This retrospective single-centre study included 160 CT-guided lung biopsies performed between January 2018 and February 2026. Environmental data from the day of biopsy were assigned from the nearest national monitoring station. The primary outcome was any pneumothorax on post-biopsy CT; the secondary outcome was drainage-requiring pneumothorax. Multivariable logistic regression included ozone exposure, emphysema, and access route through dependent lung area (ARDA). Ozone was analysed as a continuous variable per 10 μg/m3 and, exploratorily, using a ROC-derived threshold of ≥75.8 μg/m3. Restricted cubic splines assessed nonlinearity. Sensitivity models adjusted for needle size, biopsy system, operator identity, and season. Drainage-requiring pneumothorax was analysed using Firth logistic regression.
Results
Pneumothorax occurred after 86 of 160 biopsies (53.8%), and 13 biopsies (8.1%) required drainage. Ozone was not associated with pneumothorax when modelled linearly (OR, 1.09 per 10 μg/m3; 95% CI, 0.97–1.23; p = 0.167). In exploratory threshold modelling, ozone ≥ 75.8 μg/m3 was associated with pneumothorax (OR, 2.76; 95% CI, 1.39–5.61; p = 0.004). Emphysema increased pneumothorax odds (OR, 2.16; 95% CI, 1.03–4.68; p = 0.047), whereas ARDA was protective (OR, 0.23; 95% CI, 0.11–0.45; p < 0.001). Spline analysis supported nonlinearity (p = 0.001). For drainage-requiring pneumothorax, only emphysema was significant.
Conclusions
Ambient ozone showed an exploratory nonlinear association with pneumothorax after CT-guided lung biopsy, with a threshold signal around 70–80 μg/m3. ARDA was protective, whereas emphysema was associated with drainage-requiring pneumothorax.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University of Bern, Rosenbühlgasse 27, 3010 Bern, Switzerland.
- Service of Radiology, Geneva University Hospital, 1211 Geneva, Switzerland.
- Department of Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, 79110 Freiburg im Breisgau, Germany.
- Department of Radiology, Charité-Universitätsmedizin, Augustenburger Platz 1, 13353 Berlin, Germany.
- Division of Interventional Radiology, Department of Radiology, Stanford University School of Medicine, Stanford, CA 94305, USA.
ORCID-Profile: Alois Komarek, Michael Dieckmeyer, Elif Can, Martin Jonczyk, Michael P Brönnimann
Zitieren
APA
Afilal, N., Komarek, A., Dieckmeyer, M., Can, E., Jonczyk, M., Heverhagen, J. T., & Brönnimann, M. P. (2026). Ambient Ozone Exposure and Pneumothorax Risk After CT-Guided Lung Biopsy. Tomography, 12(7), 98. https://doi.org/10.3390/tomography12070098
Vancouver
Afilal N, Komarek A, Dieckmeyer M, Can E, Jonczyk M, Heverhagen JT, et al. Ambient Ozone Exposure and Pneumothorax Risk After CT-Guided Lung Biopsy. Tomography. 2026;12(7):98. doi:10.3390/tomography12070098
BibTeX
@article{Afilal2026,
author = {Afilal, Nour and Komarek, Alois and Dieckmeyer, Michael and Can, Elif and Jonczyk, Martin and Heverhagen, Johannes T and Brönnimann, Michael P},
title = {Ambient Ozone Exposure and Pneumothorax Risk After CT-Guided Lung Biopsy},
journal = {Tomography},
year = {2026},
volume = {12},
number = {7},
pages = {98},
doi = {10.3390/tomography12070098}
}
EUVIMED