EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Modification of the serratus anterior strength test to reduce confounding muscle activation: An EMG-based validation study

Christian Weber, Tobias Goetschi, Carl M Zipser

Physical Therapy in Sport · 2025

DOI: 10.1016/j.ptsp.2025.08.009 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Physical Therapy in Sport, 2025. Verfasst von Christian Weber und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physiotherapy, Balgrist University Hospital, Forchstrasse 340, 8008, Zurich, Switzerland. Electronic address: christian.weber@balgrist.…. Hauptthemen laut MEDLINE: Electromyography, Muscle Strength, Superficial Back Muscles, Muscle, Skeletal. Die Arbeit nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: To compare the seated flexion strength test (FST) with two modifications incorporating shoulder external rotation and supine positioning, aiming to improve serratus anterior (SA) selectivity through reduced upper (UT) and lower trapezius (LT) interference. DESIGN: Cross-sectional validation study using surface electromyography (EMG) and handheld dynamometry. SETTING: University hospital musculoskeletal department. PARTICIPANTS: Eighteen healthy adults. MAIN OUTCOME MEASURES: EMG activation of SA, UT, LT and pectoralis major normalized to maximum voluntary contraction; activation ratios (UT/SA and LT/SA); force measurements with handheld dynamometer. RESULTS: Both modifications significantly reduced UT (p = 0.002) and LT activation (p = 0.010-0.049) compared to the FST without significantly reducing SA activity. The ratios (median UT/SA, LT/SA) showed a non-significant trend toward reduction in modification 1 (0.53, 0.57) and modification 2 (0.60, 0.41) compared to the FST (0.83, 0.71). Only modification 2 demonstrated excellent reliability (ICC 0.97, 95 % CI:0.92-0.99, MDC 14 %). CONCLUSIONS: The modification 2 (supine positioning, shoulder external rotation, 45° tilted dynamometer) enhances SA isolation and demonstrates superior reliability compared to the FST. Therefore, it may improve clinical assessment of SA strength particularly when differentiating from UT and LT is of interest. Further research is needed before applying these findings to patient populations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectromyographyMuscle StrengthSuperficial Back MusclesMuscle, SkeletalHumansMaleCross-Sectional StudiesFemaleAdultMuscle Strength DynamometerYoung AdultReproducibility of ResultsShoulderSupine Position

Stichwörter der Autor:innen

Scapular upward rotationSerratus anteriorShoulder rehabilitationStrength testingValidity

Autor:innen und Institutionen

  • Department of Physiotherapy, Balgrist University Hospital, Forchstrasse 340, 8008, Zurich, Switzerland. Electronic address: christian.weber@balgrist.ch.
  • Clinical Trial Unit, Balgrist University Hospital, Forchstrasse 340, 8008, Zurich, Switzerland. Electronic address: tobias.goetschi@balgrist.ch.
  • Department of Neurology and Neurophysiology, Balgrist University Hospital, Forchstrasse 340, 8008, Zurich, Switzerland. Electronic address: carl.zipser@balgrist.ch.

Zitieren

APA

Weber, C., Goetschi, T., & Zipser, C. M. (2025). Modification of the serratus anterior strength test to reduce confounding muscle activation: An EMG-based validation study. Physical Therapy in Sport. https://doi.org/10.1016/j.ptsp.2025.08.009

Vancouver

Weber C, Goetschi T, Zipser CM. Modification of the serratus anterior strength test to reduce confounding muscle activation: An EMG-based validation study. Physical Therapy in Sport. 2025. doi:10.1016/j.ptsp.2025.08.009

BibTeX
@article{Weber2025,
  author = {Weber, Christian and Goetschi, Tobias and Zipser, Carl M},
  title = {Modification of the serratus anterior strength test to reduce confounding muscle activation: An EMG-based validation study},
  journal = {Physical Therapy in Sport},
  year = {2025},
  doi = {10.1016/j.ptsp.2025.08.009}
}
Kostenlos starten →