Application of Isokinetic Dynamometry Data in Predicting Gait Deviation Index Using Machine Learning in Stroke Patients: A Cross-Sectional Study
Sensors · 13.11.2024 · 24 (22) · 7258
DOI: 10.3390/s24227258 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Sensors, online erschienen am 13.11.2024. Verfasst von Xiaolei Lu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rehabilitation, Beijing Rehabilitation Hospital, Capital Medical University, Beijing 100144, China. Hauptthemen laut MEDLINE: Machine Learning, Stroke, Gait. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key Research and Development Program of China, Ministry of Science and Technology of the People’s Republic of China.
Abstract (Originalsprache)
Background
Three-dimensional gait analysis, supported by advanced sensor systems, is a crucial component in the rehabilitation assessment of post-stroke hemiplegic patients. However, the sensor data generated from such analyses are often complex and challenging to interpret in clinical practice, requiring significant time and complicated procedures. The Gait Deviation Index (GDI) serves as a simplified metric for quantifying the severity of pathological gait. Although isokinetic dynamometry, utilizing sophisticated sensors, is widely employed in muscle function assessment and rehabilitation, its application in gait analysis remains underexplored.
Objective
This study aims to investigate the use of sensor-acquired isokinetic muscle strength data, combined with machine learning techniques, to predict the GDI in hemiplegic patients. This study utilizes data captured from sensors embedded in the Biodex dynamometry system and the Vicon 3D motion capture system, highlighting the integration of sensor technology in clinical gait analysis.
Methods
This study was a cross-sectional, observational study that included a cohort of 150 post-stroke hemiplegic patients. The sensor data included measurements such as peak torque, peak torque/body weight, maximum work of repeated actions, coefficient of variation, average power, total work, acceleration time, deceleration time, range of motion, and average peak torque for both flexor and extensor muscles on the affected side at three angular velocities (60°/s, 90°/s, and 120°/s) using the Biodex System 4 Pro. The GDI was calculated using data from a Vicon 3D motion capture system. This study employed four machine learning models—Lasso Regression, Random Forest (RF), Support Vector regression (SVR), and BP Neural Network—to model and validate the sensor data. Model performance was evaluated using mean squared error (MSE), the coefficient of determination (R2), and mean absolute error (MAE). SHapley Additive exPlanations (SHAP) analysis was used to enhance model interpretability.
Results
The RF model outperformed others in predicting GDI, with an MSE of 16.18, an R2 of 0.89, and an MAE of 2.99. In contrast, the Lasso Regression model yielded an MSE of 22.29, an R2 of 0.85, and an MAE of 3.71. The SVR model had an MSE of 31.58, an R2 of 0.82, and an MAE of 7.68, while the BP Neural Network model exhibited the poorest performance with an MSE of 50.38, an R2 of 0.79, and an MAE of 9.59. SHAP analysis identified the maximum work of repeated actions of the extensor muscles at 60°/s and 120°/s as the most critical sensor-derived features for predicting GDI, underscoring the importance of muscle strength metrics at varying speeds in rehabilitation assessments.
Conclusions
This study highlights the potential of integrating advanced sensor technology with machine learning techniques in the analysis of complex clinical data. The developed GDI prediction model, based on sensor-acquired isokinetic dynamometry data, offers a novel, streamlined, and effective tool for assessing rehabilitation progress in post-stroke hemiplegic patients, with promising implications for broader clinical application.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Rehabilitation, Beijing Rehabilitation Hospital, Capital Medical University, Beijing 100144, China.
- Beijing Rehabilitation Medicine, Beijing Rehabilitation Hospital, Capital Medical University, Beijing 100144, China.
ORCID-Profile: Hujun Wang, Yingqi Li
Förderung
- National Key Research and Development Program of China
- Ministry of Science and Technology of the People’s Republic of China
Zitieren
APA
Lu, X., Qiao, C., Wang, H., Li, Y., Wang, J., Wang, C., Wang, Y., & Qie, S. (2024). Application of Isokinetic Dynamometry Data in Predicting Gait Deviation Index Using Machine Learning in Stroke Patients: A Cross-Sectional Study. Sensors, 24(22), 7258. https://doi.org/10.3390/s24227258
Vancouver
Lu X, Qiao C, Wang H, Li Y, Wang J, Wang C, et al. Application of Isokinetic Dynamometry Data in Predicting Gait Deviation Index Using Machine Learning in Stroke Patients: A Cross-Sectional Study. Sensors. 2024;24(22):7258. doi:10.3390/s24227258
BibTeX
@article{Lu2024,
author = {Lu, Xiaolei and Qiao, Chenye and Wang, Hujun and Li, Yingqi and Wang, Jingxuan and Wang, Congxiao and Wang, Yingpeng and Qie, Shuyan},
title = {Application of Isokinetic Dynamometry Data in Predicting Gait Deviation Index Using Machine Learning in Stroke Patients: A Cross-Sectional Study},
journal = {Sensors},
year = {2024},
volume = {24},
number = {22},
pages = {7258},
doi = {10.3390/s24227258}
}
EUVIMED