EUVIMEDEUVIMED entdecken
Vergleichsstudie

Effects of the particle size of monodispersed non-porous silica filler on surface, mechanical properties, and printing trueness of 3D printed dental resin

Di Chen, Gan Jin, Yifan Ma, Zhihao Zhang, Yunqi Liu, So-Hee Lee, Jong-Eun Kim

The Journal of Prosthetic Dentistry · 2026

DOI: 10.1016/j.prosdent.2026.06.025 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The Journal of Prosthetic Dentistry, 2026. Verfasst von Di Chen und 6 weiteren Autor:innen. Beteiligte Einrichtung: PhD student, Department of Prosthodontics, College of Dentistry, Yonsei University, Seoul, Republic of Korea; and Researcher, Oral Science Research C…. Hauptthemen laut MEDLINE: Silicon Dioxide, Printing, Three-Dimensional, Composite Resins. Die Arbeit nennt 57 Literaturangaben. Gefördert von: National Research Foundation of Korea.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: The customization of silica fillers represents a prevailing trend in resin improvements, yet clinicians lack clarity regarding particle size effects when selecting materials for 3-dimensional (3D) printing. PURPOSE: This study aimed to compare the effects of adding monodispersed, nonporous, spherical silica nanoparticles (150 nm) and microparticles (2.0 μm) at 1 to 2 wt% on the mechanical, surface properties, printing trueness, and biocompatibility of 3D printed dental resins, and to characterize the binary mixtures in optimizing filler selection. MATERIAL AND METHODS: A 3D printed resin (NextDent C&B resin, 3D systems) was modified with monodispersed silica particles and fabricated into test specimens. Comprehensive analyses included surface characterization (surface roughness, Ra, n=10; scanning electron microscopy, SEM, and energy-dispersive X-ray spectroscopy, EDS, n=3), degree of conversion (DC, n=10), Vickers hardness (VHN, n=10), flexural strength (FS, n=10), 3D trueness (n=10), and relative cell viability. Statistical analysis included normality testing (Shapiro-Wilk test) and analysis of variance (ANOVA) with Tukey post hoc comparisons to assess differences (α=.05). The 2-way ANOVA examined interactive effects of silica particle size and concentration. RESULTS: Microparticles at 2 wt% increased surface roughness to 142 ±12 nm (82 ±11 nm in the control group) and hardness to 15.45 ±0.24 VHN (15.14 ±0.37 VHN in the control group). The inclusion of nanoparticles at 2 wt% exerted the opposite effects, reducing the surface roughness to 46 ±7 nm, improving DC, and reducing FS to 100.46 ±8.69 MPa (138.23 ±8.29 MPa in the control group). The mixed group showed the highest DC (63.11 ±2.13%) and balanced mechanical properties. At 2 wt%, both particle types reduced printing trueness, with root mean square (RMS) error rising above 100 μm (72.62 ±2.10 μm in the control). All formulations exhibited satisfactory short-term and long-term biocompatibility. CONCLUSIONS: The monodispersed non-porous silica particles modified 3D printed dental resin. Particle size and concentration of silica critically influence resin performance. Microparticles exhibited stronger concentration-dependent effects than nanoparticles, improving VHN, FS, and Ra. Nanoparticles increased DC and resulted in smoother surfaces with lower Ra. Mixed particles offered a balanced performance through synergistic effects.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Silicon DioxidePrinting, Three-DimensionalComposite ResinsSurface PropertiesParticle SizeMicroscopy, Electron, ScanningMaterials TestingHardnessNanoparticlesPorosityFlexural StrengthCell SurvivalHumansBiocompatible MaterialsSpectrometry, X-Ray Emission

Substanzen

Silicon DioxideComposite ResinsBiocompatible Materials

Autor:innen und Institutionen

  • PhD student, Department of Prosthodontics, College of Dentistry, Yonsei University, Seoul, Republic of Korea; and Researcher, Oral Science Research Center, Yonsei University college of Dentistry, Seoul, Republic of Kore…
  • Postdoctoral Researcher, Department of Prosthodontics, College of Dentistry, Yonsei University, Seoul, Republic of Korea.
  • PhD student, Department of Prosthodontics, College of Dentistry, Yonsei University, Seoul, Republic of Korea; and Researcher, Oral Science Research Center, Yonsei University College of Dentistry, Seoul, Republic of Kore…
  • Associate Professor, Department of Prosthodontics, College of Dentistry, Yonsei University, Seoul, Republic of Korea. Electronic address: gomyou@yuhs.ac.

Förderung

  • National Research Foundation of Korea

Zitieren

APA

Chen, D., Jin, G., Ma, Y., Zhang, Z., Liu, Y., Lee, S. H., & Kim, J. E. (2026). Effects of the particle size of monodispersed non-porous silica filler on surface, mechanical properties, and printing trueness of 3D printed dental resin. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2026.06.025

Vancouver

Chen D, Jin G, Ma Y, Zhang Z, Liu Y, Lee SH, et al. Effects of the particle size of monodispersed non-porous silica filler on surface, mechanical properties, and printing trueness of 3D printed dental resin. The Journal of Prosthetic Dentistry. 2026. doi:10.1016/j.prosdent.2026.06.025

BibTeX
@article{Chen2026,
  author = {Chen, Di and Jin, Gan and Ma, Yifan and Zhang, Zhihao and Liu, Yunqi and Lee, So-Hee and Kim, Jong-Eun},
  title = {Effects of the particle size of monodispersed non-porous silica filler on surface, mechanical properties, and printing trueness of 3D printed dental resin},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2026},
  doi = {10.1016/j.prosdent.2026.06.025}
}
Kostenlos starten →