Accuracy of scannable anatomic healing abutments for implant-supported crown and fixed partial prostheses: An in vitro comparison with conventional scan bodies
The Journal of Prosthetic Dentistry · 2026
DOI: 10.1016/j.prosdent.2026.06.021 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The Journal of Prosthetic Dentistry, 2026. Verfasst von Paolo Nava und 6 weiteren Autor:innen. Beteiligte Einrichtung: Resident, Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, Mich.; and Periodontics and Oral Impla…. Hauptthemen laut MEDLINE: Crowns, Dental Prosthesis, Implant-Supported, Dental Abutments, Computer-Aided Design. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Accurate digital implant scanning is critical for the fit, function, and biological stability of implant-supported restorations. Anatomic scannable healing abutments (AHAs) have been proposed as an alternative to conventional scan bodies (SBs) to simplify digital workflows and facilitate the development of an adequate emergence profile. However, their accuracy in crown and short-span fixed dental prosthesis scenarios remains insufficiently investigated. PURPOSE: The purpose of this in vitro study was to compare the trueness and precision of implant position detection obtained using AHAs versus SBs in single-crown and short-span fixed dental prosthesis configurations. MATERIAL AND METHODS: Two partially edentulous maxillary models were digitally designed and 3-dimensionally (3D) printed: 1 with a single molar edentulous site and 1 with a 3-tooth posterior edentulous span. Implant analogs were placed in the models to simulate a single implant site and a 3-unit implant fixed dental prosthesis site. AHAs (test group) or SBs (control group) were connected to the analogs. A desktop scanner was used to obtain baseline scans for each group, while 15 consecutive intraoral scans per group were acquired using an intraoral scanner. Linear (mesiodistal, buccolingual, coronoapical), angular, and overall 3D deviations at the implant platform center were calculated and analyzed using the t test and Mann-Whitney U test. RESULTS: For the single-crown model, AHAs demonstrated significantly better mean 3D trueness than SBs (20 µm and 74 µm; P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Resident, Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, Mich.; and Periodontics and Oral Implantology Advanced Computing and Artificial Intelligence (PICO.AI), Univ…
- Undergraduate student, Department of Biomedical, Dental, and Morphological and Functional Imaging Sciences, University of Messina, Messina, Italy.
- Resident, Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, Mich.
- Assistant Professor, Department of Biologic and Materials Sciences, Division of Prosthodontics, School of Dentistry, University of Michigan, Ann Arbor, Mich.
Zitieren
APA
Nava, P., Nava, C., Dunbar, D., Galindo-Fernandez, P., Kalani, K., Sabri, H., & Li, J. (2026). Accuracy of scannable anatomic healing abutments for implant-supported crown and fixed partial prostheses: An in vitro comparison with conventional scan bodies. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2026.06.021
Vancouver
Nava P, Nava C, Dunbar D, Galindo-Fernandez P, Kalani K, Sabri H, et al. Accuracy of scannable anatomic healing abutments for implant-supported crown and fixed partial prostheses: An in vitro comparison with conventional scan bodies. The Journal of Prosthetic Dentistry. 2026. doi:10.1016/j.prosdent.2026.06.021
BibTeX
@article{Nava2026,
author = {Nava, Paolo and Nava, Carlo and Dunbar, David and Galindo-Fernandez, Pablo and Kalani, Khushboo and Sabri, Hamoun and Li, Junying},
title = {Accuracy of scannable anatomic healing abutments for implant-supported crown and fixed partial prostheses: An in vitro comparison with conventional scan bodies},
journal = {The Journal of Prosthetic Dentistry},
year = {2026},
doi = {10.1016/j.prosdent.2026.06.021}
}
EUVIMED