Influence of bruxism on occlusal force distribution in maxillary implant-supported overdentures: A finite element analysis study

Omir Aldowah, Mohammad Zarbah, Abdulmajeed Okshah, Mohammed Hamad Alyami, Mohammed Nasser Almobti, Seyed Ali Mosaddad

The Journal of Prosthetic Dentistry · 2026

DOI: 10.1016/j.prosdent.2026.05.057 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2026. Verfasst von Omir Aldowah und 5 weiteren Autor:innen. Beteiligte Einrichtung: Associate Professor, Department of Prosthetic Dental Sciences, College of Dentistry, Najran University, Najran, Saudi Arabia. Hauptthemen laut MEDLINE: Finite Element Analysis, Denture, Overlay, Dental Prosthesis, Implant-Supported, Bite Force. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Najran University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: The optimal implant number and distribution for maxillary implant-supported overdentures (IODs) in patients with bruxism remain uncertain. PURPOSE: The purpose of this study was to evaluate the biomechanical effect of bruxism on maxillary IODs with different implant configurations using polymethyl methacrylate (PMMA) and polyetheretherketone (PEEK) denture base materials. MATERIAL AND METHODS: Four 3-dimensional finite element models of maxillary IODs were developed with varying implant numbers, diameters, and positions. Models were designated according to implant configuration: R4 included 4 regular-diameter implants in the lateral incisor and first premolar regions; N4 included 4 narrow-diameter implants in the same positions; R2N1 included 2 regular-diameter posterior implants and 1 narrow-diameter midline implant; and R2 included 2 regular-diameter implants in the canine regions. Each model was analyzed with PMMA and PEEK overdentures under simulated bruxism loading (1350 N) and 3 occlusal relationships. Total deformation, von Mises stress, and fatigue behavior were evaluated. RESULTS: Implant distribution had a greater effect on biomechanical behavior than overdenture material. R4 showed the lowest cortical bone (approximately 48 to 55 MPa) and implant stresses (approximately 135 to 160 MPa), whereas N4 and R2N1 generated higher cortical bone stresses (approximately 80 to 85 MPa), approaching fatigue limits. R2 exhibited the greatest mucosal deformation (up to approximately 98 µm). PMMA overdentures showed lower deformation (

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Finite Element AnalysisDenture, OverlayDental Prosthesis, Implant-SupportedBite ForceBruxismHumansPolymethyl MethacrylateBiomechanical PhenomenaPolymersPolyethylene GlycolsBenzophenonesDental MaterialsKetonesStress, MechanicalDental Stress AnalysisDental ImplantsMaxillaDenture DesignImaging, Three-DimensionalElastic ModulusDenture BasesDenture, Complete, UpperBiocompatible MaterialsIncisorCuspid

Substanzen

Polymethyl MethacrylatePolymersPolyethylene GlycolsBenzophenonesDental MaterialsKetonespolyetheretherketoneDental ImplantsBiocompatible Materials

Autor:innen und Institutionen

  • Associate Professor, Department of Prosthetic Dental Sciences, College of Dentistry, Najran University, Najran, Saudi Arabia.
  • Associate Professor, Department of Prosthodontics, College of Dentistry, King Khalid University, Abha, Saudi Arabia.
  • Assistant Professor, Department of Allied Dental Health Sciences, College of Applied Medical Sciences, Khamis Mushait, Saudi Arabia.
  • Assistant Professor, Prosthetic Dental Sciences Department, College of Dentistry, Najran University, Najran, Saudi Arabia.
  • Private practice, Najran, Saudi Arabia.
  • PhD Candidate, Department of Conservative Dentistry and Bucofacial Prosthesis, Faculty of Odontology, Complutense University of Madrid (UCM), Madrid, Spain; and Adjunct Faculty Member, Department of Research Analytics,…

Förderung

  • Najran University

Zitieren

APA

Aldowah, O., Zarbah, M., Okshah, A., Alyami, M. H., Almobti, M. N., & Mosaddad, S. A. (2026). Influence of bruxism on occlusal force distribution in maxillary implant-supported overdentures: A finite element analysis study. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2026.05.057

Vancouver

Aldowah O, Zarbah M, Okshah A, Alyami MH, Almobti MN, Mosaddad SA. Influence of bruxism on occlusal force distribution in maxillary implant-supported overdentures: A finite element analysis study. The Journal of Prosthetic Dentistry. 2026. doi:10.1016/j.prosdent.2026.05.057

BibTeX
@article{Aldowah2026,
  author = {Aldowah, Omir and Zarbah, Mohammad and Okshah, Abdulmajeed and Alyami, Mohammed Hamad and Almobti, Mohammed Nasser and Mosaddad, Seyed Ali},
  title = {Influence of bruxism on occlusal force distribution in maxillary implant-supported overdentures: A finite element analysis study},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2026},
  doi = {10.1016/j.prosdent.2026.05.057}
}
Kostenlos starten →