EUVIMEDEUVIMED entdecken
Crossref

Accuracy of 3D scan data of extraorally digitized removable complete dentures with or without metal bases obtained with intraoral scanners

Soyeong Jeon, Ha Eun Choi, Marta Revilla-León, Kyung Chul Oh

The Journal of Prosthetic Dentistry · 2026-05 · 135 (5) · e178-e185

DOI: 10.1016/j.prosdent.2025.10.026 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2026-05. Verfasst von Soyeong Jeon und 3 weiteren Autor:innen. Beteiligte Einrichtung: Former Graduate student, Department of Industrial Dentistry, Yonsei University College of Dentistry, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Denture, Complete, Denture Bases, Denture Design, Imaging, Three-Dimensional. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 60 Literaturangaben. Gefördert von: National Research Foundation of Korea, Ministry of Education, Yonsei University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: Studies of the accuracy of extraorally digitized removable complete dentures (RCDs) acquired with intraoral scanners (IOSs) are lacking. PURPOSE: The purpose of this in vitro study was to assess the trueness and precision of extraorally digitized RCDs with or without a metal base obtained with 3 IOSs. MATERIAL AND METHODS: Three types of RCDs-a heat-polymerized resin-based maxillary (MxR group) and mandibular (MnR group) RCD, and a metal-based maxillary (MxM group) RCD-were fabricated. Three fiducial markers were attached to each RCD as reference points for scan alignment. Reference scan data were obtained by using an industrial scanner. Each RCD was extraorally scanned by using 3 IOSs: TRIOS 5, i900, and Primescan (n=10). Scan data were aligned with the reference by using 3-point and best-fit alignment methods. Trueness was assessed by using mean absolute deviation (mAD) and root mean square deviation (RMSD), while precision was determined by the standard deviation (SD) of mADs (SDmAD) and the SD of the means of original deviations (SDmOD). Statistical analyses included the Kruskal-Wallis test for trueness and Levene test for precision (α=.05). RESULTS: In the MxR group, TRIOS 5 demonstrated significantly better trueness (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Denture, CompleteDenture BasesDenture DesignImaging, Three-DimensionalHumansComputer-Aided DesignIn Vitro Techniques

Autor:innen und Institutionen

  • Former Graduate student, Department of Industrial Dentistry, Yonsei University College of Dentistry, Seoul, Republic of Korea.
  • Graduate student, Department and Research Institute of Dental Biomaterials and Bioengineering, BK21 FOUR Project, Yonsei University College of Dentistry, Seoul, Republic of Korea.
  • Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash.; Faculty and Director of Research and Digital Dentistry, Kois Ce…
  • Associate Professor, Department of Prosthodontics, Yonsei University College of Dentistry, Seoul, Republic of Korea. Electronic address: kyungabc@yuhs.ac.

Förderung

  • National Research Foundation of Korea
  • Ministry of Education
  • Yonsei University

Zitieren

APA

Jeon, S., Choi, H. E., Revilla-León, M., & Oh, K. C. (2026). Accuracy of 3D scan data of extraorally digitized removable complete dentures with or without metal bases obtained with intraoral scanners. The Journal of Prosthetic Dentistry, 135(5), e178-e185. https://doi.org/10.1016/j.prosdent.2025.10.026

Vancouver

Jeon S, Choi HE, Revilla-León M, Oh KC. Accuracy of 3D scan data of extraorally digitized removable complete dentures with or without metal bases obtained with intraoral scanners. The Journal of Prosthetic Dentistry. 2026;135(5):e178-e185. doi:10.1016/j.prosdent.2025.10.026

BibTeX
@article{Jeon2026,
  author = {Jeon, Soyeong and Choi, Ha Eun and Revilla-León, Marta and Oh, Kyung Chul},
  title = {Accuracy of 3D scan data of extraorally digitized removable complete dentures with or without metal bases obtained with intraoral scanners},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2026},
  volume = {135},
  number = {5},
  pages = {e178--e185},
  doi = {10.1016/j.prosdent.2025.10.026}
}
Kostenlos starten →