Fit assessment of different sintering speeds of multilayer zirconia using micro-CT
The Journal of Prosthetic Dentistry · 2025
DOI: 10.1016/j.prosdent.2025.04.045 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2025. Verfasst von Khaled A Elbanna und 5 weiteren Autor:innen. Beteiligte Einrichtung: Assistant Professor, Fixed Prosthodontics Division, Department of Oral and Maxillofacial Surgery, Faculty of Dental Medicine, Umm Al-Qura University,…. Hauptthemen laut MEDLINE: Zirconium, X-Ray Microtomography, Crowns, Dental Prosthesis Design. Die Arbeit nennt 48 Literaturangaben.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Data on the marginal and internal fits of speed-sintered zirconia crowns is lacking. PURPOSE: The aim of this in vitro study was to assess the marginal and internal fit of multilayer zirconia implant crowns when sintered with 3 different sintering cycles: a standard cycle (SC), a speed cycle (SP), and a superspeed cycle (SS). MATERIAL AND METHODS: A total of 30 zirconia implant crowns were fabricated and divided into 3 groups based on the speed of the sintering cycle (n=10). Microcomputed tomography was used to scan all specimens, and the marginal and internal gaps were measured. The Kruskal-Wallis and Friedman tests were used to compare the marginal and internal gaps among the groups (α=.05). RESULTS: A statistically significant difference was detected between the SC group and the other groups (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Assistant Professor, Fixed Prosthodontics Division, Department of Oral and Maxillofacial Surgery, Faculty of Dental Medicine, Umm Al-Qura University, Makkah, Saudi Arabia.
- Assistant Professor, Dental Biomaterials Division, Department of Restorative Dentistry, Faculty of Dental Medicine, Umm Al-Qura University, Makkah, Saudi Arabia.
- Assistant Professor, Removable Prosthodontics Division, Department of Oral and Maxillofacial Surgery, Faculty of Dental Medicine, Umm Al-Qura University, Makkah, Saudi Arabia. Electronic address: smnassief@uqu.edu.sa.
- Professor, Department of Fixed Prosthodontics, Faculty of Dentistry, Cairo University, Cairo, Egypt; and Associate Professor, Fixed Prosthodontics Division, Department of Oral and Maxillofacial Surgery, Faculty of Denta…
- Assistant Professor, Dental Biomaterials Division, Department of Restorative Dentistry, Faculty of Dental Medicine, Umm Al-Qura University, Makkah, Saudi Arabia; and Assistant Professor, Dental Biomaterials Department,…
Zitieren
APA
Elbanna, K. A., Redwan, H. S., Nassief, S. M., Elsayed, S. M., Yaghmoor, R. B., & Zidan, A. Z. (2025). Fit assessment of different sintering speeds of multilayer zirconia using micro-CT. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2025.04.045
Vancouver
Elbanna KA, Redwan HS, Nassief SM, Elsayed SM, Yaghmoor RB, Zidan AZ. Fit assessment of different sintering speeds of multilayer zirconia using micro-CT. The Journal of Prosthetic Dentistry. 2025. doi:10.1016/j.prosdent.2025.04.045
BibTeX
@article{Elbanna2025,
author = {Elbanna, Khaled A and Redwan, Hetaf S and Nassief, Sarah M and Elsayed, Shereen M and Yaghmoor, Rayan B and Zidan, Ahmed Z},
title = {Fit assessment of different sintering speeds of multilayer zirconia using micro-CT},
journal = {The Journal of Prosthetic Dentistry},
year = {2025},
doi = {10.1016/j.prosdent.2025.04.045}
}
EUVIMED