Development and evaluation of a noninvasive vibration modeling technique for primary stability measurement in artificial cortical bone blocks

Chester Jar, Andrew Archibald, Monica Gibson, Lindsey Westover

The Journal of Prosthetic Dentistry · 2025

DOI: 10.1016/j.prosdent.2025.04.015 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2025. Verfasst von Chester Jar und 3 weiteren Autor:innen. Beteiligte Einrichtung: Graduate student, Department of Mechanical Engineering, University of Alberta, Edmonton, Alberta, Canada. Electronic address: jar@ualberta.ca. Hauptthemen laut MEDLINE: Vibration, Cortical Bone, Dental Implants, Dental Prosthesis Retention. Die Arbeit nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Natural Sciences and Engineering Research Council of Canada, Mitacs, Suncor Energy Incorporated.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Statement of problem Noninvasive methods of quantifying stability are important for monitoring implant health. Current techniques are unable to provide a universal measurement of stability. The Advanced System for Implant Stability Testing (ASIST) is a device that noninvasively measures implant stability by analyzing the vibration response of the implant system to estimate the interfacial stiffness, reported as the ASIST Stability Coefficient (ASC).

Purpose

The aim of this in vitro study was to determine whether implant stability can be measured as the interfacial stiffness with a refined analytical model that accounts for cortical and cancellous layers. Material and methods Bone-level tapered implants were placed in polyurethane foam comprised of 2 layers mimicking cortical and cancellous bone. Cancellous bone was simulated with 320 kg/m 3 foam, while cortical bone was simulated with 3 densities (480, 640, 800 kg/m 3 ) and 3 thicknesses (1, 2, 3 mm) for a total of 9 experimental groups. Each group contained 10 specimens. The stability of each implant was measured with the ASC, Implant Stability Quotient (ISQ), insertion torque (IT), and pullout test. Two-way ANOVA was used to compare stability values across groups of the same cortical density and thickness (α=.05). The Dunnett test was also used to compare experimental groups with a control group (n=10) of purely cancellous foam (320 kg/m 3 ). Correlations between outcome measurements were described with the Pearson correlation coefficient.

Results

ASC values followed similar trends with IT and pullout force (PF) measurements where varying the cortical density had the largest effect on stability values at the highest cortical thickness and vice versa. The control group showed values similar to those of the groups with a 1-mm cortical thickness. However, ISQ values significantly increased with cortical thickness ( P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

VibrationCortical BoneDental ImplantsDental Prosthesis RetentionHumansIn Vitro TechniquesPolyurethanesDental Stress AnalysisTorqueDental Implantation, EndosseousMaterials Testing

Substanzen

Dental ImplantsPolyurethanes

Autor:innen und Institutionen

  • Graduate student, Department of Mechanical Engineering, University of Alberta, Edmonton, Alberta, Canada. Electronic address: jar@ualberta.ca.
  • Graduate student, Department of Medicine, University of Alberta, Edmonton, Alberta, Canada.
  • Associate Professor, Department of Periodontology, Indiana University School of Dentistry, Indianapolis, Ind.
  • Associate Dean, Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada.

Förderung

  • Natural Sciences and Engineering Research Council of Canada
  • Mitacs
  • Suncor Energy Incorporated
  • ITI International Team for Implantology

Zitieren

APA

Jar, C., Archibald, A., Gibson, M., & Westover, L. (2025). Development and evaluation of a noninvasive vibration modeling technique for primary stability measurement in artificial cortical bone blocks. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2025.04.015

Vancouver

Jar C, Archibald A, Gibson M, Westover L. Development and evaluation of a noninvasive vibration modeling technique for primary stability measurement in artificial cortical bone blocks. The Journal of Prosthetic Dentistry. 2025. doi:10.1016/j.prosdent.2025.04.015

BibTeX
@article{Jar2025,
  author = {Jar, Chester and Archibald, Andrew and Gibson, Monica and Westover, Lindsey},
  title = {Development and evaluation of a noninvasive vibration modeling technique for primary stability measurement in artificial cortical bone blocks},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2025},
  doi = {10.1016/j.prosdent.2025.04.015}
}
Kostenlos starten →