EUVIMEDEUVIMED entdecken
Crossref

Comparative analysis of the retention force and deformation of PEEK and PEKK removable partial denture clasps with different thicknesses and undercut depths

Wei-Fang Lee, May-Show Chen, Tzu-Yu Peng, Peng-Chien Huang, Hiroki Nikawa, Pei-Wen Peng

The Journal of Prosthetic Dentistry · 2024

DOI: 10.1016/j.prosdent.2023.09.042 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2024. Verfasst von Wei-Fang Lee und 5 weiteren Autor:innen. Beteiligte Einrichtung: Associate Professor, School of Dental Technology, Taipei Medical University, Taipei, Taiwan, ROC; and PhD student, School of Dentistry, Taipei Medica…. Hauptthemen laut MEDLINE: Chromium Alloys, Denture, Partial, Removable, Benzophenones, Polymers. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 30 Literaturangaben. Gefördert von: Ministry of Science and Technology, Taiwan, Ministry of Science and Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: The retentive force and deformation of milled polyetheretherketone (PEEK) and polyetherketoneketone (PEKK) removable partial denture (RPD) frameworks are not well understood. PURPOSE: The purpose of this in vitro study was to assess the retentive force and deformation of PEEK and PEKK Akers clasps with different designs and undercut depths. MATERIAL AND METHODS: A master model containing the first and second molar abutments was used to design Akers clasps of different cross-sectional dimensions, undercut depths (0.5 and 0.75 mm), and materials. The components of the removable partial denture framework also included an occlusal rest and were manufactured using a milling machine (n=5). The fatigue resistance of the Akers clasps was measured before and after deformation regarding the retentive forces. RESULTS: The PEEK2-U50 clasp had the largest retentive force with no significant difference among all groups before and after the insertion and removal cycle. In addition, the increased cross-sectional dimensions of the design resulted in significant differences in retentive forces between the PEEK1 and PEEK2 groups and between the PEEK and PEKK materials. CONCLUSIONS: Increasing the clasp's cross-sectional dimensions significantly impacted retentive forces, especially between different PEEK groups and between PEEK and PEKK materials.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Chromium AlloysDenture, Partial, RemovableBenzophenonesPolymersCross-Sectional StudiesDenture RetentionPolyethylene GlycolsKetonesDental Clasps

Substanzen

polyetherketoneketonepolyetheretherketoneChromium AlloysPolyethylene GlycolsKetonesBenzophenonesPolymers

Autor:innen und Institutionen

  • Associate Professor, School of Dental Technology, Taipei Medical University, Taipei, Taiwan, ROC; and PhD student, School of Dentistry, Taipei Medical University, Taipei, Taiwan, ROC.
  • Associate Professor, School of Dentistry, Taipei Medical University, Taipei, Taiwan, ROC; and Visiting Doctor, Division of Prosthodontics, Department of Dentistry, Taipei Medical University Hospital, Taipei, Taiwan, ROC.
  • Assistant Professor, School of Dentistry, Taipei Medical University, Taipei, Taiwan, ROC.
  • Dental Technician, School of Dental Technology, Taipei Medical University, Taipei, Taiwan, ROC.
  • Professor, Department of Oral Biology & Engineering, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima City, Hiroshima, Japan.
  • Professor, School of Dental Technology, Taipei Medical University, Taipei, Taiwan, ROC. Electronic address: apon@tmu.edu.tw.

Förderung

  • Ministry of Science and Technology, Taiwan
  • Ministry of Science and Technology

Zitieren

APA

Lee, W. F., Chen, M. S., Peng, T. Y., Huang, P. C., Nikawa, H., & Peng, P. W. (2024). Comparative analysis of the retention force and deformation of PEEK and PEKK removable partial denture clasps with different thicknesses and undercut depths. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2023.09.042

Vancouver

Lee WF, Chen MS, Peng TY, Huang PC, Nikawa H, Peng PW. Comparative analysis of the retention force and deformation of PEEK and PEKK removable partial denture clasps with different thicknesses and undercut depths. The Journal of Prosthetic Dentistry. 2024. doi:10.1016/j.prosdent.2023.09.042

BibTeX
@article{Lee2024,
  author = {Lee, Wei-Fang and Chen, May-Show and Peng, Tzu-Yu and Huang, Peng-Chien and Nikawa, Hiroki and Peng, Pei-Wen},
  title = {Comparative analysis of the retention force and deformation of PEEK and PEKK removable partial denture clasps with different thicknesses and undercut depths},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2024},
  doi = {10.1016/j.prosdent.2023.09.042}
}
Kostenlos starten →