Marginal fit and fracture resistance of polyetheretherketone, zirconia, and titanium implant-supported prosthesis frameworks for a partially edentulous arch after thermomechanical aging
The Journal of Prosthetic Dentistry · 2024-02 · 131 (2) · 273-280
DOI: 10.1016/j.prosdent.2023.07.015 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2024-02. Verfasst von Saadet Atsu und 1 weiteren Autor:innen. Beteiligte Einrichtung: Professor, Research Assistant, Department of Prosthodontics, Faculty of Dentistry, University of Kırıkkale, Kırıkkale, Turkey; Visiting Professor, Ma…. Hauptthemen laut MEDLINE: Dental Implants, Mouth, Edentulous, Benzophenones, Polymers. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 35 Literaturangaben.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Although polyetheretherketone (PEEK) and zirconia (Zir) have been used as implant-supported prosthesis (ISP) frameworks, the long-term effects of thermomechanical aging on the marginal fit and fracture resistance of PEEK and Zir ISP frameworks with titanium (Ti) bases for patients with a partially edentulous arch are not clear. PURPOSE: The purpose of this in vitro study was to determine the marginal fit and fracture resistance of PEEK and Zir ISP frameworks with Ti bases and Ti ISP frameworks for partially edentulous arches after aging. MATERIAL AND METHODS: A total of 30 ISP epoxy resin casts were obtained from a typodont with 1 straight implant (Nobel Biocare) in the mandibular right canine region and 1 implant with a 30-degree distal tilt in the mandibular right first molar region. All frameworks (n=10) were fabricated on their own epoxy resin cast with multiunit abutment replicas by using a computer-aided design and computer-aided manufacturing system (exocad-Yenadent). The PEEK and Zir frameworks were fabricated with Ti-bases. Primer (MKZ) and resin cement (DTK adhesive) were used to cement the frameworks to the Ti-bases under a static load of 10 N. After thermomechanical aging (1.2×106 cycles, 120 N, 5 °C-55 °C), marginal gaps between the Ti-bases and cemented frameworks and vertical and passive fits between the Ti-bases and framework and multi-unit abutments were measured by using a stereomicroscope (Euromex) at ×100 magnification. Fracture resistances and types were then determined by using a universal test machine and a stereomicroscope at ×40 magnification. Data were analyzed by using 1-way analysis of variance (ANOVA) and the Tukey HSD and Fisher-Freeman-Halton tests (α=.05). RESULTS: The marginal gaps of the PEEK and Zir frameworks were respectively 83.5 ±27.1 and 81.8 ±17.8 µm. PEEK (23.7 ±4.6) and Zir (32.9 ±8.7) had a better vertical fit (µm) than Ti (52.5 ±10.6) (P .05) frameworks had better passive fit (µm) than Ti (91.3 ±24.2). Ti had the highest mean fracture resistance (N) (14800.2 ±3442.3) followed by Zir (7318.7 ±1385.1) and PEEK (3448.9 ±486.6) (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Professor, Research Assistant, Department of Prosthodontics, Faculty of Dentistry, University of Kırıkkale, Kırıkkale, Turkey; Visiting Professor, Materials Engineering, McGill University, Montreal, Canada.. Electronic…
- Professor, Research Assistant, Department of Prosthodontics, Faculty of Dentistry, University of Kırıkkale, Kırıkkale, Turkey.
Zitieren
APA
Atsu, S., & Erol, U. (2024). Marginal fit and fracture resistance of polyetheretherketone, zirconia, and titanium implant-supported prosthesis frameworks for a partially edentulous arch after thermomechanical aging. The Journal of Prosthetic Dentistry, 131(2), 273-280. https://doi.org/10.1016/j.prosdent.2023.07.015
Vancouver
Atsu S, Erol U. Marginal fit and fracture resistance of polyetheretherketone, zirconia, and titanium implant-supported prosthesis frameworks for a partially edentulous arch after thermomechanical aging. The Journal of Prosthetic Dentistry. 2024;131(2):273-280. doi:10.1016/j.prosdent.2023.07.015
BibTeX
@article{Atsu2024,
author = {Atsu, Saadet and Erol, Ulas},
title = {Marginal fit and fracture resistance of polyetheretherketone, zirconia, and titanium implant-supported prosthesis frameworks for a partially edentulous arch after thermomechanical aging},
journal = {The Journal of Prosthetic Dentistry},
year = {2024},
volume = {131},
number = {2},
pages = {273--280},
doi = {10.1016/j.prosdent.2023.07.015}
}
EUVIMED